6
Installation Warnings
!
Failure to follow all the requirements may result in property damage, bodily injury, or death.
!
This firepit must be installed by a qualified installer.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow the
procedure best suited for the installation.
Consult Local Regulations
Consult your local city or county regulations for firepits before proceeding with installation. Local regulations
govern building and using firepits on private and public property. Some cities and regions require a burning
permit before starting an outdoor fire, and seasonal or time of day restrictions. Some firepit regulations dictate
the type of materials out of which it should be constructed. Laws may also govern what can be burned in a firepit
or how ashes are disposed.
Placement Requirements
!
For Outdoor Use Only. Install only in well-ventilated areas.
Do not locate the firepit:
In high traffic areas
Under or near trees, plants and buildings where debris may constantly fall into the firepit. Excessive debris
will require high maintenance and/or cause malfunctioning of the firepit.
In places where people, children, and pets may contact the firepit. Guards or fences around the firepit in
these locations are recommended.
Clearances:
NOTE: All clearances are measured from the outside edge of the firepit.
The distance from any structure or combustible material to the firepit perimeter shall be a minimum of 25 ft.
(7.62 M). Lesser clearances shall be used only where acceptable to the local authority having jurisdiction.
The distance from any overhanging foliage (trees, shrubs, and so on) to the firepit shall be a minimum of 15
feet (4.572 M).