Optional Equipment
4 0
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The
propane conversion kit includes pilot orifice with "35" stamped on it. Replace burner pan.
Lift the pilot hood
a
off the pilot
assembly.
5
Remove the regulator
from the front of the
gas control valve.
Replace with the
propane regulator,
using the new gasket
and screws included
with the regulator.
NOTE: Leak test
this area after the
heater is installed,
gas is connected,
and the main
burner is lit.
Travis Industries
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
NOTE: this illustration shows the gas control valve
with the inlet to the left. On the FPX 35 CB the valve
will be rotated 180°.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
9 3 5 0 8 1 1 6
(for qualified installers only)
Orifice Identification:
35
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
of the fireplace
near the gas
control valve.
LP (Propane) Orifice
35
NG (Natural Gas) Orifice
62