Section 2

2.2. Rackmount Installation

Before you start installation please verify that all
parts are included according to the package
contents.
If you want to install the KVM Switch in a 19" server
rack please attach the enclosed 19" rackmount
brackets using the screws provided.

2.3. Cascading / Daisy Chaining of multiple KVM Switches

At the time this manual was written (September 2007) the U8/16 KVM switch range may be
cascaded with other LINDY U-Series KVM switches only. Later versions of the new C5-8/16
series KVM switches will be introduced that will also be daisy chainable with the U series.
All other brands and models of KVM switches may be cascaded with LINDY U-series KVM
switches via the computer ports 1-16 of the U-series KVM switch.
To connect an additional SLAVE switch to the MASTER (or previous) switch, you must use the
included special KVM system daisy chain cable. Standard VGA cables may not work correctly
as not all cables support all pins connected.
Step 1 - Connect the local console
Connect your keyboard, mouse and monitor to the console ports of the U8/16 MASTER KVM
Switch.
Step 2 – Connect the first Slave
Use the daisy chain cable to connect the daisy chain port of the MASTER/previous KVM
Switch and the other end to the local console port of the next SLAVE switch.
Step 3 – Cascading / Daisy chaining
Repeat the previous step to daisy chain mores switches. Each individual switch in the chain
represents a different Bank. The MASTER switch is Bank 1 and each cascaded SLAVE follows
on as Bank 2, 3, 4 etc. You may cascade a maximum of eight switches/banks.
Bank 1 (Master)
Cascading KVM Switches
by daisy chaining
Hardware Installation
Bank 3... to a maximum of 8
10
Section 2
Should you wish to cascade the U-series KVM Switch with any other or the older LINDY
P-series KVM Switch then this must be done via Port cascading using the standard KVM
system cables for the computer / server ports.
Step 4 – Resetting the Switches
After you have connected and switched on the SLAVE switches and computers, all of the KVM
switches may need to be reset. First, reset the SLAVE switch at the end of the daisy chain and
then reset all of the other SLAVE switches up to the MASTER U8/16 switch.
To reset the switch, press the "B" button on the front panel of the switch.
Each SLAVE switch should then show a dash in its BANK display. Now, reset the MASTER
switch - it will show a 1 in the BANK display. Each SLAVE switch BANK display will then
change to a number according to its position in the daisy chain.
Hardware Installation
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

39533

Table of Contents