For installations utilizing an ST1175 or ST475 Square
Termination Cap the last chimney section must not be
more than 4-1/2 in. (114 mm) below the chase top. See
Figure 6.7.
Cap Standoff
1-1/2 in.
(38 mm) min.
overlap
Top of Pipe
Figure 6.7
Installing an ST1175 or ST475 Square Termination Cap
For installations utilizing an TCT1175 Terra Cotta Cap the
last chimney section must be between 7 in. (178 mm) below
the chase top and 2 in. (51 mm) above. See Figure 6.8.
1-1/2 in. (38 mm)
min. overlap
{
Top of Pipe
Figure 6.8
Installing a TCT1175 Terra Cotta Cap (available is US
only)
28
Flashing Collar
2 in. (51 mm) min.
4-1/2 in.
(114 mm)
max.
The last section of pipe
must stop between the
distances given below.
2 in. (51 mm) above top
of the chase.
7 in. (178 mm) below top
of the chase.
Heat & Glo • EXCLAIM-42 US-CAN • 4013-205 Rev D • 06/07
For chase installations you can use a TR11 or TR444
Round Termination Cap, a TR11T or TR442 Round
Telescoping Termination Cap, an ST1175 or ST475 Square
Termination Cap, or a TCT1175 Terra Cotta Termination
Cap.
For installations utilizing a European Copper Series
Termination Cap, See Figure 6.9.
Cap Base
bracket (8)
screw (8)*
chimney top
chase
top
(metal or masonry)
SL pipe
inner flue
Figure 6.9
Installing a European Copper Series Termination Cap
(CT11-King shown, available in US only)
Install termination caps following instructions provided
with them.
(cap inner flue)
2 - 6 in.
(51-152 mm)
2 in. (51 mm)
typical