B. Chase Top
A metal chase top is required to seal the top of the chase
around the chimney pipe. The top should include a turn-
down and drip edge to prevent water from seeping into the
chase. Provide a 1/8 in. (3 mm) gap around the fl ue pipe
and slope the top downward away from the penetration. See
Figure 6.4.
All seams must be caulked to prevent leaks.
A chase installation must use a chase top. Chase tops
are available from your Heatilator dealer or may be fi eld
constructed.
Attach the chase top to the top of the chase.
Caulk
Figure 6.4
Chase Top Construction
C. Install the Termination Cap
Note: To protect against the effect of corrosion on those
parts exposed to the weather, the termination cap can be
painted with a rust-resistant paint.
WARNING
Fire Risk
The minimum overlap of cap to pipe
MUST be met or chimney may separate
from cap.
Separation allows sparks, heat and embers
to escape.
Termination Cap
2 in. (51 mm) Collar
on Chase Top
Storm Collar
Slope Downward
Turn-down
Drip Edge
Chase
(Chimney)
.018 (26 ga) min.
Galvanized

Chase Top

Heat & Glo • EXCLAIM-42 US-CAN • 4013-205 Rev D • 06/07
Install the chimney sections up through the chase
enclosure. When using a TR11 or TR444 Round
Termination Cap, the uppermost top section of pipe must
extend 6 in. (152 mm) above the top of the fl ashing collar
to allow installation of the storm collar and termination cap.
See Figure 6.5.
Minimum 1-1/2 in. (38 mm) overlap of cap over pipe
6 in. (152mm) min.
Flashing Collar
Figure 6.5
Installing a TR11 or TR444 Round Termination Cap
For installations utilizing a TR11T or TR442 Round
Telescoping Termination Cap, the uppermost chimney
section must be below the top of the chase top, but not
more than 14-1/2 in. (368 mm) below the top of the chase
top. Minimum overlap of chimney and termination cap
must be 1-1/2 in. (38 mm). See Figure 6.6.
Flashing Collar
Top of Pipe
Figure 6.6
Installing a TR11T or TR442 Round Telescoping Termi-
nation Cap
Storm Collar
2 in. (51 mm) min.
2 in. (51 mm) min. collar
Storm Collar
2 in. (51 mm) min.
14-1/2 in. (368mm) max.
1-1/2 in. (38 mm) min.
overlap
27