Secure The Fireplace; Install The Refractory - Heat & Glo EXCLAIM-42 Owner's Manual

Installation and operation
Hide thumbs Also See for Heat & Glo EXCLAIM-42:
Table of Contents

Advertisement

B. Secure the Fireplace
• Position the Fireplace
This fi replace may be placed on either a combustible or
noncombustible continuous fl at surface. Follow the in-
structions for framing in Section 3.D. Slide the fi replace
into position. Be sure to provide the minimum air clear-
ance at the sides and back of the fi replace assembly.
See Section 3.B.
WARNING
Fire Risk!
Prevent contact with sagging, loose
insulation.
Do NOT install against vapor barriers or
exposed insulation.
C. Install the Refractory
We recommend two installers for hearth stone and refrac-
tory installation!
Remove back refractory from outside of fi replace by
bending tabs up and lifting refractory out of brackets.
See Figure 4.5. Bend tabs back down out of the way.
See Figure 4.6. Do not remove screws or brackets from
fi replace. If brackets are removed, fi ll holes in outer
shell with screws. Repeat this process to remove side
refractories.
Figure 4.5
Unpacking Back Refractory
Figure 4.6
Bending Refractory Shipping Tabs
Back Down
Heat & Glo • EXCLAIM-42 US-CAN • 4013-205 Rev D • 06/07
Remove smoke shield by removing fi ve screws. See
Figure 4.7. Smoke shield is located at top of fi replace
front.
Remove screens by removing screw from the end of each
screen rod. See Figure 4.8.
Front Face
Skip
Remove these screws.
Figure 4.7
Removing Smoke Shield
Figure 4.8
Removing the Screen Rods
Remove hearth stone by removing three corrugated
shipping spacers (Figure 4.9). Lift hearth stone out of
fi replace. See Figure 4.10.
Figure 4.9
Shipping Spacers
Figure 4.10 Lifting Out the Hearth Stone
Smoke Shield
Skip
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exclaim-42

Table of Contents