Delta DTB4824 User Manual page 12

Dtb series open-type temperature controller
Hide thumbs Also See for DTB4824:

Advertisement

1016H Temperature regulation value -999~+999, unit: 0.1
1017H Analog decimal setting
1018H Time for valve from full open
to full close
1019H Dead Band setting of valve
101AH Upper-limit of feedback
signal set by valve
101BH Lower-limit of feedback
signal set by valve
101CH PID parameter selection
101DH SV value corresponded to
PID value
1020H Alarm 1 type
1021H Alarm 2 type
1022H Alarm 3 type
1023H System alarm setting
1024H Upper-limit alarm 1
1025H Lower-limit alarm 1
1026H Upper-limit alarm 2
1027H Lower-limit alarm 2
1028H Upper-limit alarm 3
1029H Lower-limit alarm 3
102AH Read LED status
102BH Read pushbutton status
102CH Setting lock status
102DH CT read value
102FH Software version
1030H Start pattern number
1040H~
Actual step number setting
1047H
inside the correspond pattern
1050H~
Cycle number for repeating
1057H
the execution of the
correspond pattern
1060H~
Link pattern number setting of
1067H
the correspond pattern
Pattern 0~7 temperature set
2000H~
point setting
203FH
Pattern 0 temperature is set to
2000H~2007H
Pattern 0~7 execution time
2080H~
setting
20BFH
Pattern 0 time is set to
2080H~2087H
6.
Address and Content of Bit Register: ( First bit of reading will put into LSB, Write data = FF00H for bit set,
0000H for bit clear)
Communication write-in
0810H
selection
Temperature unit display
0811H
selection
Decimal point position
0812H
selection
0813H AT setting
0814H Control RUN/STOP setting
STOP setting for PID
0815H
program control
0 ~ 3
0.1~999.9
0~100%; unit: 0.1%
0~1024
0~1024
0~4
Only valid within available range, unit: 0.1 scale
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
0 : None (default), 1~3 : Set Alarm 1 to Alarm 3
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
Please refer to the contents of the "Alarm Outputs" for detail
b0 : Alm3, b1: Alm2, b2: F, b3: ℃, b4: Alm1, b5: OUT2, b6: OUT1, b7: AT
b0 : Set, b1 : Select, b2 : Up, b3 : Down. 0 is to push
0 : Normal, 1 : All setting lock, 11 : Lock others than SV value
Unit: 0.1A
V1.00 indicates 0x100
0 ~ 7
0 ~ 7 = N, indicate that this pattern is executed from step 0 to step N
0 ~ 99 indicate that this pattern has been executed for 1 ~ 100 times
0 ~ 8, 8 indicates the program end. 0~7 indicates the next execution pattern
number after executing the current pattern
-999 ~ 9999
Time 0 ~ 900 (1 minute per scale)
Communication write in disabled: 0 (default), Communication write in
enabled: 1
o
C / linear input (default) : 1 ,
Except for the thermocouple B, S, R type, all the other thermocouple type
are valid. (0 or 1)
OFF: 0 (default), ON : 1
0 : STOP, 1 : RUN (default)
0: RUN (default), 1: STOP
11
o
F : 0

Advertisement

loading

This manual is also suitable for:

Dtb9696Dt4848Dtb4896