Installing The Gas Cooker - Euromaid F54CW User Manual

540mm separate grill upright cooker
Table of Contents

Advertisement

Installing the gas cooker

Unpacking
Do not fit the burner crowns, burner caps and trivets
until after the cooker has been installed.
Checking gas pressures
Before installation check that the cooker is suitable for
the gas supply. To do this check the gas type on the
carton sticker or on the data plate behind the bottom of
the oven door. If the cooker is required to be used with
LPG, the supplied conversion kit must be used.
The following shows the supply and operating
pressures for various gas supplies.
Operate pressure at appliance test point:
1.00 KPa (Natural gas); N2.75 KPa (Universal LPG gas)
The following table shows the injector sizes for each
burner.
Injector
Natural gas
Auxiliary burner
Semi-rapid Burner
Triple ring Burner
Connection to the gas supply
The gas Connection must be made in accordance
with the local standards.
When installing, fit a safety tap at the end of the
pipeline. The appliance leaves the factory tested
and set for the type of gas indicated on the
plate inside the bottom guard, close to the gas
connection pipe. Make sure that the type of gas to
be supplied to the appliance is the same as that
shown on the plate.
For maximum efficiency and minimum consumption,
make sure that the gas supply pressure complies
with the values shown in the gas used is different
from that specified (or variable).a suitable pressure
regulator must be installed on the supply pipeline.
24 Euromaid 540mm Upright Cooker INSTALLING THE GAS COOKER
Universal LPG
0.93mm
0.57mm
1.16mm
0.71mm
1.75mm
1.10mm
Gas connection
A Inlet pipe joint
B Gasket
C Stable union
Procedure
Make the connection to the gas system using a rigid
metal pipe and regulation unions, or with a stainless
steel hose complying with the local standard. If metal
hoses are used, take care that they do not come into
contact with mobile parts and are not crushed.
When making the connection, take care not to apply
stresses of any kind to the appliance.
Read these points before connecting to the gas supply;
• The gas connection point is a 1/2" BSP external
thread located at the rear of the appliance as shown
in the Rear View.
• A regulator is supplied for natural gas appliances
which must be fitted in the supply line to the
appliance. For LPG the supplied brass Test Point
Adapter / Fitting must be fitted to the supply line.
• It is recommended to fit the regulator or test point
fitting to the appliance connection point, then fit
either hard piping or a flexible connection from
the regulator or test point fitting to consumer hard
piping. Ensure installation allows withdrawal of
appliance. For flexible hose installation AS/NZS
5601.1 clauses 5.9 and 6.10.1.9 must be followed.

Hide quick links: