Installing cooker – power connections
Fitting on a Power Supply Cable
WARNING:
Installtion MUST ONLY be carried out by a qualified approved installer, ie. an Electrician.
Connecting appropriate power supply ` terminal boar d/ connector block:
NOTE:
REFER to TECHNICAL tables at the rear of this manual for correct rating for your
corresponding model purchased.
• Using a screwdriver, prize open tabs of the Terminal board cover.
• Remove the wire clamp screw.
• Fasten the wires beneath the corresponding screw heads, using brass 'bridge' for single phase supply.
• Fasten cable clamp and close the cover of the terminal board.
• The AC power supply should be 220-240V, 50Hz. For electric cookers, the minimum 45A fuse, or at least 45A a
distribution circuit breaker. For gas cookers, the minimum 20A fuse, or at least 20A circuit breaker.
WARNING: Connect the power cord must be in accordance with the instructions listed in the table below
Wire cross-sectional
Connection mode
1N~
2N~
Connecting the supply cable to the mains
Install an approved circuit breaker with a minimum contact opening of 3 mm, between the appliance and the mains
fuse box. The circuit breaker should be sized according to the load and should comply with current regulations (the
earth wire should not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50ºC with respect to the
room temperature, anywhere along its length Before switching fuse ON in meter-box check:
• Earth continuity. The electrical safety of this appliance can only be guaranteed if the cooker is correctly installed
and earthed, in compliance with regulations on electrical installations.
• The electrical capacity of the system and sockets will support the maximum power of the appliance, as indicated
on the data plate
• Go to section 19 "Installing your new cooker"
NOTE: All Upright cookers must comply to local regulations to Australian Stanadrd AS/NZS 3000:2007
guidelines. Qualified Electrician will have a copy of these guides that MUST be adhered to.
L1
area (mm
)
2
Min6
Min1.5
Euromaid 540mm Upright Cooker INSTALLING COOKER – POWER CONNECTIONS 23
L2
N
Min6
Min2.5
Min6
E
Min6
Min6

Hide quick links: