2.2 PC PROGRAMMING SET-UP
Prior to programming the 1812 with the DoorKing Auto-Programming Software for Windows, the
system must have the MASTER CODE and SYSTEM SET-UP information programmed into it.
These programming functions cannot be set with the PC and must be programmed from the system
keypad.

2.2.1 Master Code

This programming step sets the system MASTER CODE. The master code is the four-digit number
required to gain access to the system memory.
NOTE: The master code cannot be programmed from an off-site location. The master code
can only be programmed from the system keypad.
Factory setting = Last 4-digits of the serial number.
1. Open the cabinet of the telephone entry system and turn the master code switch (the
small toggle switch) on.
2. Enter a four-digit master code _ _ _ _ then press * (beep).
3. Turn the master code switch off and close the cabinet.
2.2.2 System Set-up Code
These steps will program the system set-up code. The system set-up code is a four-digit number that
will program the 1812 for: 1st digit) single or multiple systems on the phone line, 2nd digit) the units
attention number, 3rd digit) the number of rings to the house allowed before the system hangs up, 4th
digit) single or double ring to the house. You will need to enter a four-digit number in step 2 (see chart
below) to set the system set-up code.
The factory default code setting is 1 7 3 1.
1. Press * 0 4 and then enter the four-digit MASTER CODE _ _ _ _ (beep).
2. Enter the four-digit SET-UP CODE _ _ _ _ and then press * (beep).
3. Press 0# TOGETHER to end this programming step (beeeeeep).
Digit
Valid
Step 2
Entries
1 st
0 or 1
2 nd
0 – 9
3 rd
2 – 9
4 th
0 or 1
If the telephone entry system is to be programmed from a PC, no other programming is required at
the system itself. Complete the 1812 programming using the Auto-Programming Software. However
– if the 1812 IS NOT on a shared phone line, then you must program Sections 2.3.5 and 2.3.6. If you
are not programming the 1812 using the software, continue with the remaining sections in this
manual.
Page 24
Enter 1 for a single system, or enter 0 when multiple systems are sharing the
phone line.
Unit attention number.
Number of rings to the house before the unit hangs up.
Enter 0 for the standard long ring, or enter 1 for the double ring.