Graco Hydra-Clean 2510 Instructions-Parts List Manual

2500psi (172 bar) operating pressure / 2900 psi (200 bar) maximum working pressure / 3000 psi (207 bar) operating pressure / 3400 psi (234 bar) maximum working pressure
Hide thumbs Also See for Hydra-Clean 2510:

Advertisement

INSTRUCTIONS-PARTS LIST
manual
This
WARNINGS and INSTRUCTIONS
READ AND RETAIN
HYDRA-CLEAN
Pressure Washers
HYDRA-CLEAN" 2510
P/N 800-901, Series A
2500psi (172 bar) OPERATING PRESSURE
2900 psi
(200 bar) MAXIMUM WORKING PRESSURE
HYDRA-CLEAN" 3009
P/N 800-900, Series A
3000
psi (207 bar) OPERATING PRESSURE
3400 psi (234 bar) MAXIMUM WORKING PRESSURE
supply
Water
tank, gun & wand assembM, hose assembly and motor starter are not included.
GRACO INC. RO. Box 1441 MINNEAPOLIS, MN 55440-1441
wntains IMPORTANT
FOR
REFERENCE
251 0,3009
@
@COPYRIGHT 1991. GRACO INC.
CDRACO

Advertisement

Table of Contents
loading

Summary of Contents for Graco Hydra-Clean 2510

  • Page 1 INSTRUCTIONS-PARTS LIST manual This wntains IMPORTANT WARNINGS and INSTRUCTIONS READ AND RETAIN HYDRA-CLEAN Pressure Washers HYDRA-CLEAN" 2510 P/N 800-901, Series A 2500psi (172 bar) OPERATING PRESSURE 2900 psi (200 bar) MAXIMUM WORKING PRESSURE HYDRA-CLEAN" 3009 P/N 800-900, Series A 3000 psi (207 bar) OPERATING PRESSURE 3400 psi (234 bar) MAXIMUM WORKING PRESSURE supply...
  • Page 2 Read and understand all instruction manuals before operating equipment. FLUlD 1NJECTlON HAZARD General Safety This pressure washer generates very pressure. Spray from the gun, leaks or tuptured components can inject fluid through your skin and into your body and cause extremely serious bodily injury including the need for amputation.
  • Page 3: Grounding Instructions

    (GFCI). EQUIPMENT MISUSE HAZARD General Safety Any misuse of the pressure washer or accessories, such as overpressurizing, modifying parts, using incompatible chemicals and fluids, or using worn or damaged parts, can cause them...
  • Page 4 KEEP CLEAR body parts. of moving parts when starting or operating the pressure washer. high pressure fluid from the gun. N N E R operate the pressure washer without all guards and interlocks installed and functioning. Follow the TERMS WARNING or DANGER Alerts user to avoid or correct conditions that could cause bodily injury.
  • Page 5: Installation

    INSTALLATION LEVEL Figure 1 Check Shipping Damage Check the unit for any damage that may have occurred in shipping. Notify the carrier Immediately any damage. Set Up Before connecting the unit, be sure the electrical setvice matches the specification in Technical Data (inside back cover) and the voltage label on the unit.
  • Page 6 6. ALWAYS observe the following CAUTIONS to avoid costly damage to the pressure washer. DO NOT allow the pressure washer to idle for more than 10 minutes. Doing recirculating water to overheat and seriously damage the pump.
  • Page 7: Trigger Safety Latch

    5. l i p holding holes are provided on the chassis, To avoid blowing the O-ring coupler, due to the high pressure In the system, never operate the pressure washer without securely mounted in the quick coupler. Flgure 3 Tips...
  • Page 8: Shutdown, Flushing And Storage

    Pressure Relief Procedure Warning before proceeding. 308-535 If the pressure washer will be exposed to freezing temperatures, drain all water out of the pump. If it must be stored in freezing temperatures, flush the unit with a pressure.
  • Page 9: Troubleshooting Chart

    TROUBLESHOOTING CHART serious reduce risk bodily injury, from inlury moving parts, always follow PROBLEM ow pressure and/or or wrong size tip. Worn ump runs rough Inlet filter clogged. packlngs, abrasives in water or Worn wear . natural Inadequate water supply. Belt slippage.
  • Page 10: Parts Drawing

    PARTS DRAWING 800-900 Hydra-Clean@ 3009 Pressure Washer 800-901 Hydra-Clean@ 25lO~Pressure Washer 308-535...
  • Page 11 PARTS DRAWING Hydra-Cleans 3009 Pressure Washer 800-900 Hydra-Cleans 2510 Pressure Washer 800-901 PART DESCRIPTION 800-643 CHASSIS 803-788 BELT GUARD 801-941 SCREW, Cap, hex hd., 5/16-18 x 1 100-214 WASHER; Lock, 5/16 100-023 WASHER, Flat, 5/16 801-817 MOTOR, 20 hp. TEFC.
  • Page 12 PARTS DRAWING 801-790 Pump Assem 308-535...
  • Page 13: Parts List

    PARTS LIST 801-790 Pump Assembly, 2500 PART NO. NO. DESCRIPTION 1 801.-781 MANIFOLD 801-468 SCREW, Cap, hex hd 3 801-469 WASHER, Lock 4 Kit O-RING 5 Kit 1 SEAT, Valve 6 Kit PLATE, Valve 7 Kit SPRING, Valve GUIDE, Valve 9 Kit 1 VALVE ASSEMBLY Kit 4 O-RING...
  • Page 14 PARTS DRAWING 803-814 Pump Assem 308-535...
  • Page 15 PARTS LIST 803-814 Pump . -... NO. DESCRIPTION 801-781 MANIFOLD 801-468 SCREW, Cap, hex hd 801-469 WASHER. Lock Kit 1 O-RING Kit 1 SEAT. Valve Kit 1 PLATE, valve Kit 1 SPRING. Valve Kit 1 GUIDE, valve Kit 1 VALVE ASSEMBLY Kit 4 O-RING Kit 4 803-419...
  • Page 16: Pump Service

    PUMP SERVICE WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warnlng before proceeding. NOTE: The following metric wrenches are needed: M10, Mi3 and M30.
  • Page 17: Wand Assembly

    Servicing the V-Packings NOTE: There are two types of packing kits: one is packings only, the other packings, rings and retainers. 1. Remove the manifold as outlined in the Pumping Section. Carefully pull the packing retainer from the manifold. Examine the O-ring and replace it if it is cut or damaged.
  • Page 18: Technical Data

    Water Pumo Maximum Flow Dimensions Length Width Height Maximum Inlet Water Temperature wetted parts High Pressure H o s e Bypass Pressure Washer (including fittings) 308-535 Model 800-901 phase 20 HP, amp/3 phase or 2% voIff50 amp13 phase voIff.25 bar)
  • Page 19: Important Phone Numbers

    THE GRACO WARRANTY WARRANTY AND DISCLAIMERS Graoawarmntsallequipmentmanufactursdby~andbearingitsnametobefreefmmdefectslnmaterial and workmanship the date of sale by an authorized Graw distributor Aspurohaser'ssolemmedyforbreachofthiswarranty,Gramwill,foraperiodoltwentyfourmonthsfmm dateofsale,repairorrepiaceanypartdtheequipmentprovende~~.Thiswarr~appliesonlywhen the equipment Is installed. operated and maintained in recommendations. T h i s warranty does not cover, and Gram shall n d be liable for, any malfunction. damage or wear by fauity installation.

This manual is also suitable for:

Hydra-clean 3009Hydra-clean 308-535800-900800-901

Table of Contents