Grounding

The sprayer must be grounded. Grounding reduces the
risk of static and electric shock by providing an escape
wire for the electrical current due to static build up or in
the event of a short circuit.
The sprayer cord includes a grounding wire with an
appropriate grounding contact.
The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
ti2810a
Do not modify plug! Tampering with the plug will result in
a voided warranty. If plug will not fit in outlet, have
grounded outlet installed by a qualified electrician. Do
not use an adapter.

Power Requirements

100-120V units require 100-120 VAC, 50/60 Hz,
15A, 1 phase.
230V units require 230 VAC, 50/60 HZ, 10A,
1 phase.

Extension Cord

Use an extension cord with an undamaged ground con-
tact. If an extension cord is necessary, use a 3-wire, 12
2
AWG (2.5 mm
) minimum.
Ground
120 volt plug
3A0157A

Pails

Solvent and oil/based fluids: follow local code. Use
only conductive metal pails, placed on a grounded sur-
face such as concrete.
Do not place pail on a nonconductive surface such as
paper or cardboard which interrupts grounding continu-
ity.
Grounding a metal pail: connect a ground wire to the
pail by clamping one end to pail and other end to a true
ti4297a
earth ground.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of spray gun firmly
to side of a grounded metal pail. Then trigger gun.
ti5850a
ti14840a
ti13243a
Grounding
9