Preparation; Pressure Relief Procedure; Grounding; Power Requirements - Graco RTX2500 Operation, Parts

Interior texture sprayers
Hide thumbs Also See for RTX2500:
Table of Contents

Advertisement

Preparation

Pressure Relief Procedure

Follow the Pressure Relief
Procedure whenever you see this
symbol.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid or splashed fluid follow the Pressure
Relief Procedure whenever sprayer is
stopped and before sprayer is cleaned or
checked, and before equipment is
serviced.
1.
Turn ON/OFF switch to the OFF
position. Wait 7 seconds for power to
dissipate.
ti27340a
2.
On the RTX1400si, trigger gun into
material hopper.
3A3258H
3.
Open air control valve.
4.
On the RTX2000pi and RTX2500pi,
open gun prime valve.

Grounding

The equipment must be grounded to
reduce the risk of static sparking and
electric shock. An electric or static spark
can cause fumes to ignite or explode. An
improper ground can cause electric shock.
A good ground provides an escape wire for
the electric current.
This sprayer includes a ground wire with an
appropriate ground contact. The plug must
be plugged into an outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
Do not modify the plug provided; if it does not
fit the outlet, have the proper outlet installed
by a qualified electrician.

Power Requirements

100-120V units require 100-120 VAC, 50/60
Hz, 12 or 15A, 1 phase. 230V units require
220-240 VAC, 50/60 Hz, 10A

Extension Cords

Use an extension cord with an undamaged
ground contact. If an extension cord is
necessary, use a 3-wire, 12 AWG (2.5 mm
minimum.
Preparation
ti27341a
2
)
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtx2000Rtx1400

Table of Contents