240 Vac Filter Board - Graco 1095 Premium Hi-Boy Instruction Manual

Electric airless sprayers for portable airless spraying of architectural coatings and paints
Table of Contents

Advertisement

Perform Pressure Relief Procedure; page 8.
Removal
1. Remove four screws (38) and cover (96).
2. Disconnect display connector (A) from motor control
board (52).
3. Remove bottom two screws (39). disconnect poten-
tiometer connector (C) from motor control board
(52). Disconnect power cord connectors (D) and fil-
ter board connectors (J) from ON/OFF switch (33)
and remove control panel (68).
4. Disconnect WatchDog switch connector (X) and
reed switch connector (L) from motor control board.
5. Disconnect motor control board power connectors
(K) from filter board (146).
240 VAC
96
38
39
39
3A0157A

240 VAC Filter Board

5
52
146
61 K
C
163
A
A
J
A
33
C
82
L
68
82
34
115
6. Remove four screws (163) from filter board (146).
Installation
1. Install filter board (146) with four screws (163).
2. Connect motor control board power connectors (K)
to filter board (146).
3. Connect filter board power connectors (J) to top two
terminals of ON/OFF switch (33) and power cord
connectors (D) to bottom two terminals of ON/OFF
switch.
4. Connect potentiometer connector (C) to motor con-
trol board (52).
5. Connect WatchDog switch (X) and reed switch con-
nector (L) to motor control board.
6. Install control panel (68) with two screws (39).
7. Connect display connector (A) to motor control
board (52).
8. Install cover (96) with four screws (38).
26
52
A
E
E
80
20
67
Troubleshooting
F
H
G
ti14890a
X
23

Advertisement

Table of Contents
loading

Table of Contents