Outlet
This drop down menu is used to select the outlet for which the options below will apply.
-Outlet 1 or Outlet 2: Selects the built-in outlets.
Automatic Reboot
When this option is set to On, WebSwitch™ will operate in Automatic Reboot mode. In Automatic
Reboot mode, WebSwitch™ is configured to periodically confirm that another device (such as a
server, computer, router, etc.) is working by sending ping requests to the device. WebSwitch™
expects a response after each ping. If a pre-set number of ping requests fail, it is assumed that the
device is not functioning properly. WebSwitch™ will attempt to restore the device to normal
operation by rebooting the device. In Automatic Reboot mode, users still have the ability to
manually reboot the device from a remote location over the network. The default setting for this field
is Off.
When automatic reboot is set to Off, WebSwitch™ will operate in Normal mode. In Normal mode,
WebSwitch™ will only change the state of the outlets when commanded by a user.
Outlet Description
This text field is used to describe the function of the selected outlet. The text appears to the left of
the corresponding outlet status on the Control Page, and in the email message when email alerts
are enabled. Up to 24 characters may be entered in this field. The default text is Outlet #.
On Button Label
The text entered in this field appears in the 'On' button for the corresponding outlet on the Control
Page. Up to 15 characters may be entered in this field. The default text is ON.
Off Button Label
The text entered in this field appears in the 'Off' button for the corresponding outlet on the Control
Page. Up to 15 characters may be entered in this field. The default text is OFF.
Pulse/Reboot Button Label
The text entered in this field appears in the 'Pulse' button for the corresponding outlet on the Control
Page. Up to 15 characters may be entered in this field. The default text is REBOOT.
On Status Text
The text in this field specifies the text that will be displayed in the status field in the Control Page and
in email messages when the corresponding outlet is on. Up to 15 characters may be entered in this
field. The default text is ON.
Off Status Text
The text in this field specifies the text that will be displayed in the status field in the Control Page and
in email messages when the corresponding outlet is off. Up to 15 characters may be entered in this
field. The default text is OFF.
Xytronix Research & Design, Inc.
WebSwitch™ Users Manual
45

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WebSwitch XRDI-WS3 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Webswitch xrdi-ws3p

Table of Contents