Mitsubishi Electric FR-A7NS Instruction Manual page 45

Plug-in option sscnet iii communication function 700 series
Table of Contents

Advertisement

INVERTER SETTING AND DISPLAY
CAUTION
In the SSCNET ΙΙΙ operation mode, the Pr. 79 Operation mode selection setting is invalid.
Changes in the shaft number are reflected only at the next power-on. Therefore, if the shaft number is
changed, make sure to power off and on the inverter power.
Even if SSCNET ΙΙΙ operation is being performed,
of the PU (FR-DU07/FR-PU07) can be used to make
a stop (when Pr. 75 Reset selection/disconnected PU detection/PU stop selection = "14 (factory setting) to 17").
At this time, the deceleration time is 0s. Refer to the inverter manual for Pr. 75.
In addition, "
" is displayed in the PU. However, an alarm output is not provided. (Refer to page 76.)
REMARKS
During SSCNET ΙΙΙ operation, "NET" is displayed to indicate the operation mode.
5
39