Dispensing Fluid and Operation Mode Screens
Preset Dispense (F
Preset Meters Only
MOBIL1 5W-20
D
H
J
G
ti122410a
F
. 22
IG
See F
. 22 for terms D - L
IG
D. Information Banner: Configurable information
banner. Data is input in Setup Mode, Banner Screen,
page 17.
E. Unit of Measurement: Identifies unit of
measurement, pint, quart, gallon or liter. Unit is selected
in Setup Mode, Units/Limit Screen, page 13.
F. Home Icon: Returns user to Home Screen.
G. Reset: Resets counter (H) to zero.
H. Counter: Before dispense has begun, display reads
0.00. As fluid is dispensed, counts up from zero. At the
same time the Progression Bar (J) displays a real-time,
visual representation of the progress made toward
completing the dispense.
J. Progression Bar: Displays a real-time, visual
representation of the progress made toward completing
the dispense. Runs in conjunction with Counter (H).
For example, in F
. 22, a partial dispense of 2.5 quarts
IG
of the total Preset Dispense of 5.0 quarts is shown. The
Progression Bar shows that approximately half the
dispense is complete.
20
. 22)
IG
2.50
QTS
E
4.0
L
L. Preset Quantities: Use the UP or DOWN ARROW to
select field L on the task bar.
a.
Use the UP or DOWN ARROWS to scroll
through the 3 available Preset Quantities (L).
Each time you press the UP or DOWN
ARROWS, one of the 3 preset amounts dis-
plays on the task bar in field L.
b. When the Preset Quantity you want to dispense
is shown in field L, press the center, ENTER
button to select it.
If a suitable preset quantity is not available, select
an amount that is closest to the amount you want to
dispense. Amounts can be modified following the
procedure described on page 21.