Place reusable electrostatic-sensitive parts from assemblies in
protective packaging or non-conductive foam.
Use transporters and conveyers made of antistatic belts and roller
bushings. Ensure that mechanized equipment used for moving
materials is wired to ground, and that proper materials were selected
to avoid static charging. When grounding is not possible, use an
ionizer to dissipate electric charges.
Use the following grounding precautions at workstations:
Cover the workstation with approved static-dissipative material
(refer to Table 4-2 later in this chapter).
Use a wrist strap connected to a properly grounded work surface and
use properly grounded tools and equipment.
Use field service tools, such as cutters, screwdrivers, and vacuums
that are conductive.
When using fixtures that must directly contact dissipative surfaces,
use fixtures made of static-safe materials only.
Keep work area free of nonconductive materials such as ordinary
plastic assembly aids and Styrofoam.
Handle electrostatic-sensitive components, parts, and assemblies by
the case or PCM laminate. Handle them only at static-free
workstations.
Avoid contact with pins, leads, or circuitry.
Turn off power and input signals before inserting or removing
connectors or test equipment.