Testing The Dispensers; Making Timed Deposits Of Medium To Thick Fluids - EFD 900 Operating Manual

900 series dispenser
Table of Contents

Advertisement

Testing the Dispensers

Making Timed Deposits of Medium to Thick Fluids

(Model 900)
You are now ready to test the pre-filled, nontoxic, blue test fluid. This
material is representative of thick, non-leveling fluids like sealants,
pastes or greases.
Check your initial settings:
A) Air gauge reads 30 psi.
B) Timer is set at #7.
C) Green tapered tip is on the test barrel.
D) Power and timer bypass switches are on.
Holding the barrel as shown, rest the tip on a piece of paper. Press
the foot pedal until the tip fills and some fluid is pushed out onto the
paper. Repeat this whenever you change to a new tip.
With the tip filled, turn off the timer bypass switch (yellow light out).
Take the Dot Test sheet and put the tip on a 1/4" circle, holding the
barrel as shown. Press the foot pedal. Check the dot size. Make
several more similar dots and note the size consistency.
Remember – When the yellow timer bypass switch is on, a continuous
flow of material will occur as long as the foot pedal is pressed. The
yellow light must be off to make timed deposits.
8
7
8
6
2
Timer
Pressure
Correct angle for consistent deposits.
Remember
- always bring the tip in
contact with the work surface at
the illustrated angle. After the tip is
in position, press the foot pedal.
Release pedal and remove tip by
lifting straight up.