1500XL -- Setup for Testing
Power switch
should be off.
The amount of material dispensed each cycle depends on the
combination of air pressure, time of air pulse, viscosity of material
and dispensing tip size.
Note: The following steps refer to the 1500XL dispenser. For the
1500XL-15 and 1500XL-CA dispensers, refer to "Making Timed
Deposits of Watery-thin Fluids" on page 22.
The first step is to remove the tip cap from the prefilled barrel of blue
test material (twist and pull). Replace it with an 18 gage (green)
tapered dispensing tip. Press the tip on and twist clockwise to lock.
Pull out air pressure regulator knob
unlocked position. Turn clockwise to adjust the air pressure to 30 psi
(2.1 bar) for the initial tests.
Always set the pressure desired by turning the air regulator knob
clockwise. To reduce the pressure, turn the knob counterclock-
wise until the gauge
increase and stop at desired pressure. Push knob in to lock.
Press power switch
to turn on the dispenser. The digital display
will show the time that was set when the dispenser was turned off.
Set the digital time to 0.25 seconds as follows:
On the display and control pad
until the decimal is moved to the left and appears in the left display
segment. This puts the time range within 0.00 to 0.99 seconds. (
Now, use the time set buttons
Press the bottom right button until a 5 shows. Then press the bottom
middle button until a 2 shows. Finally, press the bottom left button
until a 0 shows. This display is equal to 0.25 seconds.
Be sure barrel vacuum control
vacuum pressure gauge
Please continue to page 20 for test procedures.
until it "clicks" into the
reads a lower pressure than desired. Then
, press the decimal button
to set the length of the air pulse.
is turned off. In the initial tests, the
will indicate zero pressure.
Refer to pages 6 - 7 for
complete details on the
microprocessor controls.
0
(
Fig. 1)
Note: For .000 time, the
decimal is not indicated.
Instead, the 000 display
Fig. 1)
is shown.
0
(Fig. 2)
(Fig. 2)
0
.
2
5
.
0
0
.
2
5
11