Troubleshooting; Power Indicator Is Not Lit; No Sound; Protection Indicator Is Lit - Rotel RB-1592 Owner's Manual

Table of Contents

Advertisement

English

Troubleshooting

Most difficulties in audio systems are the result of poor or wrong
connections, or improper control settings. If you encounter problems,
isolate the area of the difficulty, check the control settings, determine
the cause of the fault and make the necessary changes. If you are
unable to get sound from the RB-1592, refer to the suggestions for the
following conditions:

Power Indicator Is Not Lit

No main power to the RB-1592. Check AC power connections at the
amplifier and the AC outlet. Check the front panel power switch. Make
sure that it is set to the ON position.

No Sound

If the amp is getting AC power, but is producing no sound, check
the PROTECTION INDICATOR on the front panel. If lit, see below. If
not, check all of your connections and control settings on associated
components.

Protection Indicator Is Lit

The front panel PROTECTION INDICATOR lights when the RB-1592
protection circuits have shut off the amplifier. Typically, this occurs
only when the ventilation openings are blocked, when there is faulty
speaker wiring, or after a period of extreme use. Turn off the system
and wait for the amp to cool. Then push the front panel power
switch in and out to reset the protection devices. If the problem is
not corrected or reoccurs, there is a problem with the system or the
amplifier itself.
Specifications
Continuous Power Output
(20-20k Hz, <0.03%)
Total Harmonic Distortion (20Hz - 20kHz, 8 ohms)
Intermodulation Distortion (60Hz:7kHz, 4:1)
Damping Factor (20Hz-20kHz, 8ohms)
Input Impedance/Sensitivity
Amplifier Gain
Frequency Response (±1db)
S/N Ratio (IHF A)
Crosstalk / Separation
Speaker Impedance
Power Requirements
Power Consumption
Standby
Dimensions (W x H x D)
Weight (net)
Panel Height
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co.,
Ltd.,Tokyo, Japan.
9
380 watts/ch into 8 ohms
700 watts/ch into 4 ohms
< 0.03%
< 0.03%
1000
12 kohms/2.6 volts
26.5dB
10Hz - 100Khz
125 dB
> 70 dB
4 ohms minimum
USA: 120 volts, 60Hz
Europe: 230 volts, 50Hz
800 watts
Idle: 70 watts
<0.5 watt
431 x 237 x 410 mm
17 x 9
x 16
in
3/8
1/8
40 kgs, 88.18 lbs
5U/221mm/8
in
3/4

Advertisement

Table of Contents
loading

Table of Contents