Figure 4 - J600 Ethernet connection

Power Connection

Ensure power is off when cabling the power connectors.
The power connection is via terminal J800.
Connect the +12V or +24V to the terminal labelled + of J800, and 0V to the terminal labelled 0V of
J800.
Figure 5 - J800 power connection
The power wiring must be less than 3m in length and use wires having core areas of at least
2
0.5mm
.
Tamper
If an additional tamper connection is required, connect the tamper switch to GPIP 12.
Antenna
The antenna provided is a flat type and must be mounted indoors, on a flat horizontal surface,
sufficiently close that it can be connected to the Redcare Secure unit. The antenna is self-adhesive
and will bond firmly to any clean, dry and flat surface. Make a suitable hole, (typically 11mm
diameter) in the top of the box in which the Redcare Secure unit is fitted. Prevent swarf from
entering the enclosure as it could cause internal short circuits.
Remove any burrs from the hole, pass the RF cable through it and place the antenna in position.
Do not permanently fix the antenna until a Signal Strength Test has been performed.