Chapter 3
Power Supply Installation
Follow these steps to install a dual-hole lug on the switch. Be sure to follow any grounding requirements
at your site.
Use a Phillips screwdriver or a ratcheting torque screwdriver with a Phillips head to remove the ground
Step 1
screw from the cable side of the switch. You need the screw in Step 4.
Strip the 6-gauge ground wire to 0.5 inch (12.7 mm) ± 0.02 inch (0.5 mm) (see
Step 2
more than the recommended amount of wire can leave exposed wire from the connector.
Figure 3-3
0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)
Insert the ground wire into the terminal lug, and crimp the terminal to the wire (see
Step 3
Figure 3-4
Step 4
Slide the ground screw from Step 1 through the terminal lug. Insert the ground screws into the opening
on the cable side.
Figure 3-5