IC Realtime 1U Series User Manual page 40

Standalone dvr
Hide thumbs Also See for 1U Series:
Table of Contents

Advertisement

Please refer to the following sheet for alarm input and output connection. See Figure 3-13 and
Figure 3-14.
Figure 3-13 Standard 1U Series
Figure 3-14 Simple Entry Level Series
There are two alarm input types for you to select: normal open (NO) and normal close (NC).
1. Alarm input
a. Please make sure alarm input mode is grounding alarm input.
b. Grounding signal is needed for alarm input.
c. When you are connecting two DVRs or you are connecting one DVR and one other device,
please use a relay to separate them,
2. Alarm output
The alarm output port should not be connected to high power load directly (It shall be less than
1A) to avoid high current which may result in relay damage. Please use the co contactor to
realize the connection between the alarm output port and the load.
3. How to connect PTZ decoder
a. Ensure the decoder has the same grounding with DVR, otherwise you may not control the PTZ.
Shielded twisted wire is recommended and the shielded layer is used to connect to the grounding.
b. Avoid high voltage. Ensure proper wiring and some thunder protection measures.