IC Realtime 1U Series User Manual page 126

Standalone dvr
Hide thumbs Also See for 1U Series:
Table of Contents

Advertisement

Please refer to the following sheet for detailed information.
Parameter Function
Event
There are three types: Motion detection/video loss/Camera Masking.
Type
Channel
Select channel name from the dropdown list.
Enable
You need to draw a circle to enable motion detection function.
There are six levels. The sixth level has the highest sensitivity.
Sensitivity
Region
There are six levels. The sixth level has the highest sensitivity.
Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown as in
7-41
you can go to full-screen display mode. Do remember clicking OK
button to save your motion detection zone setup.
Period
Motion detection function becomes activated in the specified
periods.
There are six periods in one day. Please draw a circle to enable
corresponding period.
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
Click OK button, system goes back to motion detection interface;
please click save button to exit.
System only memorizes one event during the anti-dither period. The
Anti-dither
value ranges from 0s to 15s.
Normal
There is 2-channel alarm output.
out
Corresponding to motion detection alarm output port(multiple
choices)
Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.
System can delay the alarm output for specified time after alarm end
Alarm
The value ranges from 10s to 300s.
latch
Alarm
System can upload the alarm signal to the centre (Including alarm
upload
centre.
Record
System auto activates motion detection channel (multiple choices) to
channel
record once alarm occurs (working with motion detection function).
Please note you need to go to Chapter 4.4 Schedule to set motion
detection record period and go to chapter 4.2 Manual Record to set
current period as auto record.
Record
System can delay the record for specified time after alarm ended. The
latch
value ranges from 10s to 300s.
Email
If you enabled this function, System can send out email to alert you
when alarm occurs and ends.
Tour
Display the selected video in local monitor window.
Tour interval and tour mode are set in DVR local menu (chapter
5.3.9 Display )
. There are PAL 22X18/NTSC 22X15 zones. Right click mouse
X
F igure
X 4 6 9 H 4 6 9 H 4 6 9 H
126

Advertisement

Table of Contents
loading