Technical Data / Nozzle Table - Gaggenau CG 492 Operating Instructions Manual

Gas cooker
Hide thumbs Also See for CG 492:
Table of Contents

Advertisement

11. Technical Data / Nozzle Table

Technical data (gas)
Burners:
Normal burner
Full burning
Low burning
Large burner
Full burning
Low burning
Wok burner
Full burning
Low burning
Total output
Countries
Gas family
Gas type
Pressure
Nozzle, full burn, outer
Nozzle, low burn, outer
Nozzle, full burn, inner
Nozzle, low burn, inner
Air gap adjustm. outer [mm]
Air gap adjustm. inner [mm]
Total output
Total consumption
* open, fixed
18
2.0 kW
0.165 kW
4.0 kW
0.165 kW
5.0 kW
0.3 kW
17.0 kW
Nozzle table wok burner
AT BE CH CZ
DE DK ES FI
FR GB GR HU
IE IS IT LU NL
PL PT RU SE
Natural gas
H / E / L (G 20/25)
20/25 mbar
1.55
0.73
0.58
0.45
0
*
17 kW
1.70 m
3
/h
Gas connection: R 1/2'' union nut for R 1/2''
bracket to DIN 1999, conical-cylindrical
Technical data (electrical)
Rated consumption
Voltage
Frequency
Technical modifications reserved.
DE
BE CH CZ DK
ES FI FR GB
GR HU IE IS
IT LU NO PL
PT RU
Natural gas
LPG/Propane
LL (G 25)
3 + (G30/31)
20 mbar
28-30/37 mbar
1.70 B
1.00
0.81
0.51
0.63
0.37
0.51
0.31
0
0
*
*
17 kW
17 kW
1.87 m
3
/h
1240 g/h
15 W
AC 220-240 V
50-60 Hz
AT CH DE
LPG/Prop.
(G30/31)
50 mbar
0.87
0.45
0.33
0.25
–2
*
17 kW
1240 g/h

Advertisement