If the unit is not working properly, this may be due to small problems that you can easily resolve yourself.
Follow these instructions carefully before contacting your local Authorised Technical Service Centre.
PROBLEM
The air conditioner is
completely turned
off
the air conditioner is
on but the applian-
ce doesn't start
The unit works but
does not cool the
room
The appliance does
not function and the
problem warning
light
is turned
on.
26
16:27
Pagina 26
Troubleshooting
CAUSE
•
it is not plugged in
there is no electricity
•
•
the safety device has switched on
•
the timer pin is in the OFF position
•
The teeth of the timer are in the rest mode
•
three minutes have not passed since it was
turned on
•
windows open
•
a heat source is operating in the room (burner,
light, etc.) or there are a lot of people
•
the air outlet hose has come detached from
the coupling
•
thermostat adjusted too high
•
air filters clogged
•
the output of the unit is insufficient for the con-
ditions or size of the room
the tube is blocked
•
the tube is twisted or folded
•
the filter is obstructed or dirty
•
REMEDY
•
plug in
•
wait
•
contact the Service Centre
•
adjust the timer
•
proceed with a new setting of
the timer
•
wait three minutes (safety devi-
ce) before the appliance start
cooling.
•
close the windows
•
eliminate heat sources
•
fit the hose in the coupling
•
lower the thermostat
•
clean/replace filters
remove the blockage from the
•
tube
position the tube correctly
•
press the "manual resetable"
•
button, which is found inside the
tank housing