DESCALING
When using the appliance in water mode, lime scale will inevi-
tably form and must be removed to maintain efficiency. After
about 500 hours of operation, the appliance therefore warns that
descaling is required by displaying the message
Descale the appliance.
• Turn off the appliance and unplug from the mains. Empty all
water from the inside of the appliance through the drain
hoses (fig. 42).
• Close and replace the drain hoses. Pour 0.5 l of descaler (one
bottle) and 1.5 l of clean water into the tank.
• Plug in and operate the appliance in air conditioning mode
with the BOOST function selected until the
symbol appears on the display.
• Turn off the appliance and unplug from the mains. Empty all
water from the inside of the appliance through the drain
hoses.
• Close and replace the drain hoses. Pour 2 l of clean water into
the tank and rinse the internal circuits of dirt and descaler.
• Plug in and operate the appliance until the
symbol appears on the display.
• Turn off the appliance and unplug from the mains. Empty all
rinsing water from the inside of the appliance through the
drain hoses.
• If the water drained off is very dirty or contains large quanti-
ties of foam, repeat the rinsing operation.
• Close the drain hoses and replace.
• After descaling, reset the alarm by pressing the
10 seconds.

TECHNICAL CHARACTERISTICS:

Power supply voltage
Max. power input
during air conditioning
Absorbed power heating
(certain models only)
Refrigerant
Cooling capacity
L
IMIT CONDITIONS
Room temperature for air conditioning
Room temperature for heating
(certain models only)

GUARANTEE AND TECHNICAL ASSISTANCE

The conditions of the guarantee and technical assistance are
given on the certificate supplied with your appliance.
CL (CLEAN).
"no water"
"no water"
button for
see rating plate
"
"
"
"
MAX 25°C21÷35°C
MAX 25°C
39

If you think there may
be a large amount of
water left in the tank,
before descaling, perform
the "forced draining" pro-
cedure.
465mm
570mm
910mm