INSTALLATION

Battery Cable Fusing

A fuse is required by the NEC to protect
the battery and cables. A UL Listed DC rated
slow blow fuse must be installed in the positive
(+) battery cable, within 18 inches of the
battery.
Recommended Fuse: UL Listed Class T
JLLN with a DC Rating. This fuse with fuse
holder is available from your dealer or Xantrex.
For Freedom 10
200 Amp Fuse & Holder PN# 84-4155-00 (C/R)*
200 Amp Fuse & Holder PN# 84-4158-00 (R/R)**
200 Amp Fuse Only
For Freedom 15 & 15D
200 Amp Fuse & Holder PN# 84-4155-00 (C/R)*
200 Amp Fuse & Holder PN# 84-4158-00 (R/R)**
200 Amp Fuse Only
COMPRESSION / RING TERMINAL
INVERTER
CABLE
WARNING
Improper stack up of hardware will cause
excessive heat and fuse failure. Stack up
as shown.
28
PN# 84-4157-00
PN# 84-4157-00
NUT
LOCK WASHER
FLAT WASHER
BATTERY
CABLE
FUSE
FUSE HOLDER
For Freedom 20 & 20D
300 Amp Fuse & Holder PN# 84-4156-00 (C/R)*
300 Amp Fuse & Holder PN# 84-41554-00 (R/R)**
300 Amp Fuse Only
For Freedom 25
300 Amp Fuse & Holder PN# 84-4156-00 (C/R)*
300 Amp Fuse & Holder PN# 84-4154-00 (R/R)**
300 Amp Fuse Only
For Freedom 30
350 Amp Fuse & Holder PN# 84-4159-00
350 Amp Fuse Only
* Compression / Ring Terminal
** Ring / Ring Terminal
_
+
EXPLODED VIEWS
OF FUSE ASSEMBLY
RING / RING TERMINAL
INVERTER
CABLE
PN# 84-4117-00
PN# 84-4151-00
PN# 84-4152-00
+ (red)
NUT
LOCK WASHER
FLAT WASHER
BATTERY
CABLE
FUSE
FUSE HOLDER