14. Information
Information regarding the heat detector (11):
We care about your safety. For that reason we have installed a thermo sensor (11) at this air
purification center that functions as follows.
If directly under the exhaust hood a temperature between 69 ° C and 71 ° C is reached, a siren sounds
automatically and the power supply to the device is interrupted. After cooling down to ca. 30 ° C – 35 ° C
the siren automatically goes of again.
Information regarding the ionizer:
The ionizer freshens the air. The negative ions clean the air from very fine dust particles, from bacteria
floating in the air on positive ions, from floating viruses and fungal spores. Through the airflow caused
by the built-in motor, particles are carried to a metal filter where they deposit. Those deposits are
removed by cleaning the upper metal filters (3) on a regular basis.
Using the ionizer is not hazardous! Even from high dose of negative ions doesn't do you any harm. A
high dose of positive ions however can make you sick, tired, slackly, sometimes even irritated and
aggressive.
Information regarding the disinfection radiator (14):
This disinfection radiator is a special low-pressure mercury vapor radiator emitting short-wave ultra
violet radiation whereas the disinfecting effect of which is by far superior to the one of natural solar
irradiation. It destroys effectively all microorganisms such as bacteria, viruses, spores, yeasts, algae,
protozoa, and mold fungi – and all that without ozone!
!! Since UV-C radiation is hazardous to the eye, never look directly into the turned on lamp !!
WARNING:
Touching the lamp with bare hands causes spots. Always use a clean cloth or wear clean gloves!
If quartz glass was touched by hands, it must be cleaned first using little alcohol before putting it in
operation.