Electrolux 350 Installation Instructions Manual

Electrolux hepa central air filtration system home owners manual & dealer installation instructions
Hide thumbs Also See for 350:

Advertisement

AIR CLEANERS/FILTERS
HEPA CENTRAL AIR FILTRATION SYSTEM
HOMEOWNERS MANUAL & DEALER INSTALLATION
INSTRUCTIONS
FOR MODELS 350 & 675
Rules for Safe Installation and Operation
READ AND SAVE THESE INSTRUCTIONS!
Please read instructions before installing and using the HEPA Central Air
Filtration System (HEPA system). This will help you obtain the full benefit of
the HEPA system you have selected. It will also help you to avoid needless
service costs.
. Read this manual carefully. Failure to follow these rules and instructions
could cause a malfunction of the air filter or unsatisfactory service and
could void your warranty.
2. Follow a regular service and maintenance schedule to ensure efficient
operation.
3. For safety and optimized performance of your HEPA system, all
installation and maintenance must be performed by a professional heating
and ventilation contractor. The installer should be made aware of your
indoor air quality situation and be familiar with your heating, ventilation and
air conditioning equipment.
4. High particulate distribution may occur during initial start-up of this product
after installation or after scheduled filter changes. Individuals who are
highly sensitive to airborne particulates should not be in the building and
allow 24 hours of operation for removal of particulates from occupied
spaces before re-entry.
Risk of property damage, injury or death.
Installation, adjustments, alterations, service and maintenance must be
performed by a qualified technician.
Risk of Carbon Monoxide Poisoning.
Can cause injury or death. Do not operate equipment without access
panel in place. Operation of this equipment without all access panels
in place may cause gas fumes from the heating system to be drawn
into occupied spaces.
Shipping and Packing List
Package  of  contains:
 - HEPA System
 - Complete Filter Set (Packed inside Unit)
 - Installation Kit
 - Installation Instructions (this manual)
 - Registration Card
 - Warranty Statement
HEPA System Models
Model 350 is designed to filter air up to a rate of 350 cfm.
Model 675 is designed to filter air up to a rate of 675 cfm.

Table of Contents

Rules for Safe Installation and Operation ......................................................
Shipping and Packing List ...........................................................................
Introduction .................................................................................................2
General Information .....................................................................................2
Product Application Guidelines ....................................................................2
Parts Identification .......................................................................................3
Physical Dimensions of Units .......................................................................3
Dealer Installation Instructions .................................................................. 4-6
Operation ....................................................................................................6
Maintenance ................................................................................................7
Filter Change Schedule ................................................................................7
Filter Changing Guidelines ...........................................................................7
Dealer Filter Change Instructions .................................................................8
Dealer Motor Assembly Replacement Instructions .......................................9
Electrical Diagram ........................................................................................9
Beam Central HEPA Air FIltration Systems Item List ...................................0
Part Inventory ............................................................................................


Advertisement

Table of Contents
loading

Summary of Contents for Electrolux 350

  • Page 1: Table Of Contents

     - Registration Card  - Warranty Statement HEPA System Models Model 350 is designed to filter air up to a rate of 350 cfm. Model 675 is designed to filter air up to a rate of 675 cfm. Table of Contents Rules for Safe Installation and Operation ......
  • Page 2: Introduction

    Introduction Congratulations! You will quickly realize that you have purchased a very effective air cleaning system. It incorporates state of the art HEPA (High Efficiency Particulate Air) technology. Your HEPA system comes with a limited warranty. With proper attention to its care and maintenance, you will receive optimum performance. If your indoor air has abnormally high concentrations of particulates, the life span of the filter media may be shortened.
  • Page 3: Parts Identification

    Parts Identification Cabinet Parts Filter Section Access Panel Retaining Clips (2) Intake Collar Cabinet Outflow Collar Control Panel Motor Section Access Panel Power Cord Filter parts identification HEPA Cartridge Parts HEPA Filter Pre-Filter - Foam HEPA Filter Mesh (Protects HEPA Filter) Inner Carbon Filter Physical dimensions of unit...
  • Page 4: Dealer Installation Instructions

    Air Handler/ Furnace Handler/Furnace Filter HEPA System Required Materials for Installation of Unit: Items for 350 Flex or rigid duct (length as required) Takeoffs Items for 675 Flex or rigid duct (length as required) Takeoffs All Models Aluminum tape or mastic as required Misc.
  • Page 5 • For best indoor air quality, do not use ductboard or fiberglass inside of ducts. Electricity: • The unit must be plugged into a grounded 20V, 60Hz outlet. Required Materials for Installation of Unit: Items for 350 Flex or rigid duct (length as required) Takeoffs Items for 675...
  • Page 6: Operation

    NOTE: Be sure to review ‘Rules for Safe Installation and Operation’ on page  of this document before start-up of this unit. Operation (350 & 675)  Make sure that the unit is plugged into a grounded power source (20 Volt, 60 Hz).
  • Page 7: Maintenance

    Maintenance Proper care and maintenance of your HEPA system will ensure years of service. The unit must be turned off during service/maintenance or when filters are being changed. It is recommended that gloves and a filtered breathing mask be worn during filter replacement.
  • Page 8: Dealer Filter Change Instructions

    Dealer Filter Change Instructions WARNING Electrical Shock Hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. Do not operate equipment without access panels in place. CAUTION Risk of Sharp Edges Hazard. Equipment sharp edges can cause injuries. Avoid grasping equipment edges without protective gloves.
  • Page 9: Dealer Motor Assembly Replacement Instructions

    Dealer Motor Assembly Replacement Instructions WARNING Electrical Shock Hazard. Can cause injury or death. Disconnect all electrical power supplies before servicing. Do not operate equipment without access panels in place. CAUTION Risk of Sharp Edges Hazard. Equipment sharp edges can cause injuries. Avoid grasping equipment edges without protective gloves.
  • Page 10: Beam Central Hepa Air Filtration Systems Item List

    Beam Central HEPA Air Filtration Systems Item List Beam Model 350 Central Hepa Air Filtration System & Replacement Filters HEPA Cartridge Replacement 5" Annual Filter Kit 5" Standard Replacement Components For Beam Model 350 Central Hepa Air Filtration Systems Filter Cabinet Lid...
  • Page 11: Part Inventory

    Beam Central HEPA Air Filtration Systems (models 350/675) PART INVENTORY with item numbers Filter Lid: same part for all models (172001) Filter Assembly: HEPA cartridge, foam prefilter, carbon inner blanket. See “Replacement Filters” on page 10. Filter Lid Latch: attached to cabinet.
  • Page 12 Electrolux Central Vacuum Systems 700 W. Second Webster City, IA USA 50595 visit our website at www.beam.com...

This manual is also suitable for:

Favorit 675Beam 350Beam 675

Table of Contents