Sensor Poisons And Contaminants - Honeywell GasAlertMicro 5 User Manual

Gas detector
Table of Contents

Advertisement

GasAlertMicro 5/PID/IR
User Manual

Sensor Poisons and Contaminants

Several cleaners, solvents, and lubricants can contaminate and cause
permanent damage to sensors. Before using cleaners, solvents, and
lubricants in close proximity to the detector sensors, read and adhere
to the following caution and table.
Use only the following BW Technologies by Honeywell
recommended products and procedures:
• Use water based cleaners.
• Use non-alcohol based cleaners.
• Clean the exterior with a soft, damp cloth.
• Do not use soaps, polishes, or solvents.
6
a Caution
The following table lists common products to avoid using around
sensors.
Table 2. Sensor Poisons and Contaminants
Cleaners and
Lubricants
Brake cleaners
Lubricants
Rust inhibitors
Window and glass
cleaners
Dishsoaps
Citrus based cleaners
Alcohol based
cleaners
Hand sanitizers
Anionic detergents
Methanol
(fuels and antifreezes)
Silicones
Aerosols
Silicone cleaners
Bug repellents
and protectants
and sprays
Silicone based
Lubricants
adhesives, seal-
ants, and gels
Hand/body and
Rust inhibitors
medicinal creams
that contain silicone
Tissues containing
Window and
silicone
glass cleaners
Mold releasing
agents
Polishes