1500-12 iFlex Flexible Current Probe specifications
Measuring range
Nondestructive current
Intrinsic error at reference condition*
Accuracy 1730 + iFlex
Temperature coefficient over operating temperature range
Working voltage
Probe cable length
Probe cable diameter
Minimum bending radius
Output cable length
Weight
Transducer cable material
Coupling material
Output cable
Operating temperature
Temperature, non-operating
Relative humidity, operating
IP rating
Warranty
*Reference condition:
• Environmental: 23 °C ± 5 °C, no external electrical/magnetic field, RH 65 %
• Primary conductor in center position

Ordering information

1730/BASIC Three-Phase Electrical Energy logger (excludes current probes).
1730/US Portable Energy Logger US version
1730/EU Portable Energy Logger EU version
1730/INTL Portable Energy Logger INTL version
Accessories
i1730-flex1500 iFlex flexible current probe 1500A 12 inch
i1730-flex3000 iFlex flexible current probe 3000A 24 inch
i1730-flex6000 iFlex flexible current probe 6000A 36 inch
i40s-EL i40s-EL Clamp-on Current Transformer
i1730-flex1500/3pk iFlex flexible current probe 1500A 12 inch, 3 pack
i1730-flex3000/3pk iFlex flexible current probe 3000A 24 inch, 3 pack
i1730-flex6000/3pk iFlex flexible current probe 6000A 36 inch, 3 pack
i40s-EL/3pk i40s-EL Clamp-on Current Transformer, 3 pack
1730-TL0.1M Test Lead Set; 1000 V CAT III, straight plug; 0.1 m; silicone; red/black
1730-TL2M Test Lead Set, 1000 V CAT III; straight plug; 2 m; PVC red/black
3PHVL-1730 Cable Assembly, Voltage Test Lead 3-Phase+N
C1730 1730 Soft Case
WC100 Color Localization Set
1730-Hanger Hanging strap
1730-Cable AUX input cable
6 Fluke Corporation
Fluke 1730 Three-Phase Electrical Energy Logger
Shop for Fluke products online at:
1 to 150 A ac / 10 to 1500 A ac
100 kA (50/60 Hz)
± 0.7 % of reading
± (1 % of reading + 0.02 % of range)
0.05 % of reading/°C 0.09 % of reading/°F
1000 V CAT III, 600 V CAT IV
305 mm (12 in)
7.5 mm (0.3 in)
38 mm (1.5 in)
2 m (6.6 ft)
115 g
TPR
POM + ABS/PC
TPR/PVC
-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor
under test shall not exceed 80 °C (176°F)
-40 °C to +80 °C (-40 °F to 176 °F)
15 % to 85 % non-condensing
IEC 60529:IP50
One-year
MyFlukeStore
www.
Fluke. The Most Trusted Tools
in the World.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2013 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 8/2013 4314073B_EN
Pub ID: 12028-eng Rev. 01
Modification of this document is not permitted
without written permission from Fluke Corporation.
1.877.766.5412
.com

Advertisement

loading

This manual is also suitable for:

1730/us1730/eu1730/intl1730