Controls - Stanley G5000S Owner's Manual

Hide thumbs Also See for G5000S:
Table of Contents

Advertisement

WARNING
The engine was shipped without engine oil. DO NOT START THE
ENGINE WITHOUT FILLING THE ENGINE WITH OIL. Use SAE 10W-
30 for normal conditions and SAE 5W-30 when the ambient tem-
perature is below 32° F.
Choke Rod
The choke is used to
provide an enriched
fuel mixture when
starting a cold engine.
It can be opened and
closed by operating
the choke rod manu-
ally. Pull the rod out
toward CLOSED to
enrich the mixture for
cold starting. Open
once the engine is
running.
Turn clockwise
to turn fuel valve
on.
Fuel Valve Lever
The fuel valve is lo-
cated between the fuel
tank and carburetor.
When the valve lever is
in the ON position, fuel
is allowed to flow from
the fuel tank to the
carburetor. Be sure to
return the fuel valve
lever to the OFF posi-
tion after stopping the
engine.
Engine Switch
To start and stop the engine.
Engine ON / OFF / Start Switch
(electric start shown)
Rev. 5/2010
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.

Controls

No part of this publication can be printed or copied without written permission.
Recoil Starter
To start the engine, pull the starter grip lightly until resistance is felt,
then pull briskly.
NOTICE:
Do not allow the starter grip to snap back against the engine. Return it
gently to prevent damage to the starter.
The recoil starter is used to start the engine if the generator is not
equipped with a 12 volt battery to operate the starter motor, or if the
battery does not contain adequate charge to operate the starter motor.
RECOIL STARTER
Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by
an insufficient amount of oil in the crankcase. Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert system will automati-
cally stop the engine (the engine switch will remain in the ON position).
The Oil Alert system should not take the place of checking the oil level
before each use. If the engine stops and will not restart, check the
engine oil level (see page 14) before troubleshooting in other areas.
Ground Terminal
The generator ground terminal is connected to the
frame of the generator, the metal non-current-
carrying parts of the generator, and the ground
terminals of each receptacle.
WARNING
Before using the ground terminal, consult a qualified electrician,
electrical inspector or local agency having jurisdiction for local
codes or ordinances that apply to the intended use of the genera-
tor.
NOTE: SYSTEM GROUND IS CONNECTED TO THE AC NEUTRAL ON
THIS GENERATOR. CONSULT AN ELECTRICIAN WHEN CONNECT-
ING THIS GENERATOR TO YOUR HOME OR BUSINESS ELECTRICAL
PANEL TO ENSURE GROUNDING MEETS THE LOCAL ELECTRICAL
CODE
Models: G5000S & G8000S
STARTER GRIP
9 of 16