Product Specifications - Stanley G5000S Owner's Manual

Hide thumbs Also See for G5000S:
Table of Contents

Advertisement

DANGER
AC Applications
Before connecting an appliance or power cord to the generator:
1.
Make sure that appliances are in good working order.
Faulty appliances or power cords can create a potential for
electrical shock. If an appliance begins to operate abnor-
mally, becomes sluggish or stops suddenly, turn it off imme-
diately.
2.
Disconnect the appliance, and determine whether the prob-
lem is the appliance, or if the rated load capacity of the
generator has been exceeded.
3.
Make sure that the electrical rating of the tool or appliance
does not exceed that of the generator. Never exceed the
maximum power rating of the generator. Power levels be-
tween rated and maximum may be used for no more than 30
minutes.
Substantial overloading will open the circuit breaker. Ex-
ceeding the time limit for maximum power operation or
slightly overloading the generator may not switch the circuit
breaker or circuit protector OFF, but will shorten the service
life of the generator.
Limit operation requiring maximum power to 30 minutes. For
continuous operation (longer than 30 minutes), do not exceed
80% of the rated power balanced equally on the A&B sides of
the Alternator.
DANGER
Generator
Rated frequency
Rated voltage
Rated output power
AC output (Max.)
Engine type
displacement
Compression ratio
Rated rotation speed
Rated power
Starting system
Rotation direction
Fuel type
Low oil shutdown
Fuel tank size
Oil type / Capacity
Gross weight
Battery
Integrated voltmeter
Rev. 5/2010
STANLEY is a registered trademark of The Stanley Works or its affiliates and are used under license by GXi Outdoor Power LLC.
WARNINGS
Changing the speed of the generator by adjusting the governor can cause damage to the genera-
tor, devices attached to the generator, and may result in bodily injury. Do not adjust or tamper
with the engine speed setting.

Product Specifications

5.0 kW (Max.)
OHV 4-Stroke
Counter clockwise
Unleaded gasoline
SAE 10W-30 0.9 quarts
207 lbs (94 kg)
No part of this publication can be printed or copied without written permission.
WARNING
Failure to properly follow maintenance instructions and pre-
cautions can cause serious injuries or death. Always follow
the inspection and maintenance recommendations and
schedules in this owner's manual.
Safety Precautions:
Make sure the engine is off before you begin any maintenance
or repairs. This will eliminate several potential hazards:
Carbon monoxide poisoning from engine exhaust.
Be sure there is adequate ventilation whenever you
operate the engine.
Burns from hot parts.
Let the engine and exhaust system cool before touch-
ing.
Injury from moving parts.
Do not run the engine unless instructed to do so.
In the State of California a spark arrestor is required by law.
Other states may have similar laws. Federal laws apply on all
federal lands. If you equip the muffler with a spark arrestor, it
must be maintained in effective working order. See page 11.
Rapid retraction of the recoil starter cord can pull the
starter cord back faster than you can let go. When starting
the engine, pull the cord slowly until resistance is felt then
pull rapidly to avoid kickback
G5000S
60 Hz
120V / 240V
20.8A
279 cc
8.2:1
3600 RPM
10 Hp
Recoil
Recoil and electric starter
Yes
12 gallons
N/A
Yes
Models: G5000S & G8000S
.
G8000S
60 Hz
120V / 240V
8.0 kW (Max)
33.3A
OHV 4-Stroke
401 cc
8.0:1
3600 RPM
15 Hp
Counter clockwise
Unleaded gasoline
Yes
12 gallons
SAE 10W-30 1.1 quarts
235lbs (107kg)
12 AH 12 VDC
Yes