Download Print this page

Omron E5AF Operation Manual page 49

Fuzzy temperature controller

Advertisement

4--1--2
Terminals
Terminal no.
Signal name
1
DSL1
2
DSL2
3
DSL3
4
DSL4
5
DSL5
6
DSL6
7
------
8
WD1
9
WD2
10
WD3
11
WD4
12
VAL
13
GND
14
RD1
15
RD2
16
RD3
17
RD4
18
BUSY
19
------
20
------
21
------
22
------
23
24 VDC
24
24 VDC
25
GND
Connectors
E5AF-A20 terminal identifications and functions are shown below.
13
25
Signal
direction
Input
Data select code 2
Input
Data select code 2
Input
Data select code 2
Input
Data select code 2
Input
Data select code 2
Input
Data select code 2
------
------
Input
Write data 2
Input
Write data 2
Input
Write data 2
Input
Write data 2
Input
Effective signal
------
Output side power supply 0 V
Output
Read data 2
Output
Read data 2
Output
Read data 2
Output
Read data 2
Output
BUSY signal
------
------
------
------
------
------
------
------
------
24 VDC output side power supply (must be supplied from an external
power supply)
------
24 VDC output side power supply (common with terminal 23)
------
24 VDC output side power supply (common with terminal 13)
Plug:
XM4A-2521 (OMRON) or equivalent.
Hood: XM2S-2511 (OMRON) or equivalent.
1
14
Description
0
1
2
3
4
5
0
1
2
3
0
1
2
3
Section 4--1

Advertisement

loading

This manual is also suitable for: