General Maintenance - Weber Genesis 5000 LP Owner's Manual

Propane fixed piping system
Table of Contents

Advertisement

General Maintenance

Weber Spider Stopper Guards
Your Weber Gas Barbecue, as well as any outdoor gas
appliance, is a target for spiders and other insects. They
can nest in the venturi section of the burner tubes.
This blocks the normal gas flow, and can cause the
gas to flow back out of the air shutter. Figure 6. This
could result in a fire in and around the air shutters,
under the control panel, causing serious damage to
your barbecue.
Venturi
Air shutter
Figure 6
The Weber Spider Stopper Guard is factory installed. It
fits tightly around the air shutter section of the burner
tube and the valve, thereby preventing spiders and other
insects access to the burner tubes through the air
shutter openings. Figure 7.
Weber Spider
Stopper Guard
Figure 7
We recommend that you inspect the Weber Spider
Stopper Guards at least once a year. (See section
"Annual Maintenance".) Also inspect and clean the
Spider Stopper Guards if any of the following
symptoms should ever occur.
1. The smell of gas in conjunction with the burner
flames appearing yellow and lazy.
2. Barbecue does not reach temperature.
3. Barbecue heats unevenly.
4. One or more of the burners do not ignite.
DANGER
Failure to correct these symptoms
may result in a fire which can cause
serious bodily injury or death and cause
damage to property.
Venturi fin
Main Burner Flame Pattern
The Weber Gas Barbecue burners have been factory set
for the correct air and gas mixture. The correct flame
pattern is shown in Figure 8.
Burner inside
cooking box
Flames
If the flames do not appear to be uniform the length of the
burner tube, follow the burner cleaning procedures.
Main Burner Cleaning Procedure
Turn off the gas supply. Remove the manifold.
(See Section "Replacing the main burners".)
Look inside each burner with a flashlight. Figure 9.
Clean the inside of the burners with a wire
(a straightened out coat hanger will work). Figure 10.
Check and clean the air shutter opening at the ends of
the burners. Check and clean the valve orifices at the
base of the valves. Use a brass bristle brush to clean
outside of burners. This is to make sure all the burner
ports are fully open.
CAUTION: Do not enlarge the burner ports
when cleaning.
34
Tips occasionally yellowish
Light blue
Dark blue
Figure 8
Figure 9
Figure 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesis 5000 series

Table of Contents