Figure 3.4 Multipath Connection (Switch Connection) - Fujitsu ETERNUS DX80 S2 User Manual

Disk storage system site planning
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 3 Connections
3.1 Host Connections

Figure 3.4 Multipath connection (switch connection)

Server
HBA
HBA
Switch
Port
Port
CA
CM#0
ETERNUS DX Disk storage system
When configuring multipathing for reliability, make sure to configure a redundant connection for the
controllers of the ETERNUS DX Disk storage system. Configure paths to connect to different controllers
(CM#0 and CM#1). Combinations of host interface numbers (CA#0 and CA#1) in controllers do not need
to be taken into consideration.
Paths from a single server should be separately connected to a different host interface in case of host
interface failure.
Cluster configuration
When a server is duplicated in a cluster configuration and the ETERNUS DX Disk storage system is shared by
multiple servers, software to control the cluster configuration is required.
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Site Planning-
Server
Server
HBA
HBA
HBA
HBA
Switch
Port
Port
CA
CM#1
50