Power Supply Units; Table 1.3 Lan Port Specifications For Controllers; Table 1.4 Pwc Port Specifications - Fujitsu ETERNUS DX80 S2 User Manual

Disk storage system site planning
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 1 Hardware Configurations
1.1 Controller Enclosure
LAN ports
Two LAN ports (RJ-45) are installed in each controller.
Each LAN port is used for operation management (MNT port) and for remote support function (RMT port)
respectively.
The following table shows the LAN port specifications.
Table 1.3
LAN port specifications for controllers
Ethernet
(1000Base-T/100Base-TX/10Base-T)
SCU
A System Capacitor Unit (SCU) is installed in a controller as a backup power source in case of power outage.
The SCU is charged from an external power source while the ETERNUS DX Disk storage system is running nor-
mally. If a power failure is detected, data in the cache memory is saved to the non-volatile memory in the con-
troller using the SCU. There is no limit to the post-failure data retention time.
PWC ports
A PWC port is installed in a controller.
The PWC port is used to connect a power synchronized unit to perform power synchronization.
The following table shows the PWC port specifications.
Table 1.4
PWC port specifications
RS232C
1.1.2

Power Supply Units

The power supply unit transforms input AC power from a power socket to DC power and supplies power to each
component. Two power supply units are installed in each controller enclosure.
Each power supply unit contains fans.
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Site Planning-
Transfer speed
Interface
Interface
Copyright 2013 FUJITSU LIMITED
Connector type
(max.)
1Gbit/s
RJ-45
Connector type
Number of ports for each controller
PWC
17
Number of ports
for each controller
2
1
P3AM-4822-12ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents