Working With Fiber-Optic Ports; Contents Of The Box - McAfee IIP-M80K-ISAA - Network Security Platform M-8000 Product Manual

Intrushield ips
Hide thumbs Also See for IIP-M80K-ISAA - Network Security Platform M-8000:
Table of Contents

Advertisement

McAfee® IntruShield® IPS 4.1
M-8000 Sensor Product Guide

Working with Fiber-Optic ports

The IntruShield M-8000 sensor uses fiber-optic connectors for its Monitoring ports.
The connector type is a Small Form-factor Pluggable (SFP) fiber optic connector that
is LC-Duplex compatible.
Warning:
optic port. Invisible radiation might be emitted from the aperture of the port when no
fiber cable is connected.

Contents of the box

The following accessories are shipped in the M-8000 sensor crate:
To avoid electric shock, do not connect safety extra-low voltage (SELV)
circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV
circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports
both use RJ-45 connectors. Use caution when connecting cables.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Fiber-optic ports (for example, SFP/XFP, FDDI, OC-3, OC-12, OC-48, ATM,
GBIC, and 100BaseFX) are considered Class 1 laser or Class 1 LED ports.
These products have been tested and found to comply with Class 1 limits of
IEC 60825-1, IEC 60825-2, EN 60825-1, EN 60825-2, and 21CFR1040.
To avoid exposure to radiation, do not stare into the aperture of a fiber-
Only FDA registered, EN 60825-1 and IEC 60825-1 certified Class 1 SFP
laser transceivers are acceptable for use with the M-8000 sensor.
two sensors (M-8000 P and M-8000 S).
two power supplies.
four CD-ROMs containing the sensor software and on-line documentation.
power cords. McAfee provides a standard and international power cables.
two sets of rack mounting rails.
two set of rack mounting ears.
four XFP interface modules.
two LC-LC fiber-optic cables.
one Ethernet cable.
two printed Slide Rail Assembly Procedure.
two printed Quick Start Guide.
Release Notes.