Your Guarantee - Worcester GREENSTAR i SYSTEM User Manual

Wall hung rsf gas fired condensing system boiler
Hide thumbs Also See for GREENSTAR i SYSTEM:
Table of Contents

Advertisement

11 YOUR GUARANTEE

This boiler is guaranteed against faulty materials or workmanship for a period of 2 years from the date
of installation subject to the following terms and conditions.
During the period of this guarantee any components of the boiler which are proven to be faulty or
defective in manufacture will be exchanged or repaired free of charge by Bosch Thermotechnology
Ltd.
The householder may be asked to prove the date of installation, that the boiler was correctly
commissioned and, where appropriate, the first year's service has been carried out to the
satisfaction of Bosch Thermotechnology Ltd., when requested. These should be part of the
Benchmark Checklist.
The boiler has been used only for the normal domestic purposes for which it was designed.
This guarantee does not affect your statutory rights.
GUARANTEE REGISTRATION
Returning the card will register you as the owner of your new gas boiler and will assist us in maintaining
an effective and efficient customer service by establishing a reference and permanent record for your
boiler.
FOR YOUR OWN RECORD:
Please ensure that the Benchmark Checklist has been completed by your installer or service engineer.
Model
1)
Serial No.
Type/size
Date of installation
Name of Installer
Telephone number of Installer
Tab. 3
1) See identity label on control panel/flap or Benchmark Checklist.
6 720 644 864a (2010/10)
YOUR GUARANTEE
21

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GREENSTAR i SYSTEM and is the answer not in the manual?

Questions and answers

Martin
March 11, 2025

I can’t get my green star I to stay operating it keeps turning off

User image 67cffd7aae42d
1 comments:
Mr. Anderson
March 11, 2025

The Worcester Greenstar i System boiler may keep turning off due to several possible reasons:

1. No Power – Check if the boiler has a permanent mains supply. Inspect Fuse F1 (2.5A) or Fuse F3 (0.5A) and the transformer. If faulty, replace the control board.

2. No Live Demand – Ensure there is a live demand at ST10-L from an external room thermostat or timer. Some older thermostats may not return proper voltage.

3. Diverter Valve Issue – If the boiler operates without a live demand signal, check that no permanent live feed is present at ST10-L from another source.

4. Incorrect Piping – Ensure the cold inlet and DHW outlet are correctly piped and not crossed.

5. Flow Turbine Issue – If the boiler is not operating during hot water demand, test the flow turbine.

Further troubleshooting may require checking the control board and other electrical components.

This answer is automatically generated