Programming the GEM-P816 & GEM-P1632 (v.9A and Earlier)
26
INTERIOR
BYPASS
INTERIOR
BYPASS
(Direct Entry)
27
BYPASS
INTERIOR
BYPASS
INTERIOR
(
Direct Entry)
A
A
User #
DATA ENTRIES
OPTION ENABLED
L
R
blank(•)
blank(•)
blank(•)
1
blank(•)
2
blank(•)
3
blank(•)
4
blank(•)
Add 8
* User Program
D
Press
to save. To proceed to the next User Code, press the
and change it using the number buttons.
If the programmed code was less than 6 digits, enter blanks G0 for the remaining digits.
Example: Program a code of "2222" for user 02, with area 1 options of "Arm/Disarm" and "User Program":
Enter
for the user number,
02
"(blank) 9" for area 1 options and
G09
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described
D
above and press
to save. Similarly, to cancel a code, blank out each number of the code press

Central Station Receiver 1 Format

From the table below, enter the central station's receiver format. Use number
buttons
FIRE/TBL
SYS TBL
CHIME
0
letters B–E, respectively. Press
proceed.
FIRE/TBL
SYS TBL
CHIME
NOTE: Central Station Receiver 2 and 3 Formats can only be entered in
Direct Address Programming. See CS Receiver Options.

Enter User Codes

For default program, enter up to 32 User Codes, with Area 1 and Area 2
Options. Press the (
FIRE/TBL
SYS TBL
CHIME
Use the number buttons
by
A
FIRE/TBL
SYS TBL
CHIME
NOTE:
"Global Ambush Code" (Address 1054) is left blank(•), do not program the
first two digits of ANY User Code as '99'.
User Code
USER AREA OPTIONS - Select the desired Area Options (Area 1 and
Disabled
User Code not active in this area.
Arm/Disarm
Allows User Code to arm/disarm this area.
Arm Only
Prevents User Code from disarming this area.
Service
A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, the area can be disarmed
with any valid User Code, including a Service Code. If the area is armed with OTHER than a Service Code, it
CANNOT be disarmed with a Service Code.
Access
This is normally used to activate a door striker while an area is disarmed. Also program "Access Control on PGM2
Output" (Address 0719) and "PGM2 Output Access Control Timeout" (Address 0711).
User Program Option is enabled for Keypad 1 only, wherever it is connected (Area 1 or Area 2).
2222 G0 G0
through
1
9
for a blank space (•). Press
DATA
CS RECEIVER 1 FORMAT
ENTRY
•(blank) Ademco Slow, Silent Knight Slow
2
Radionics Fast
3
Silent Knight Fast
4
Radionics, CD, Franklin Slow
) button once to set the cursor to the User Code.
A
0
and a User Code of up to 6 digits. Enter
If "Enable Global Ambush Code"(Address 0720) is enabled and
Area 1
Area2
Options
Options
EXPLANATION
A
G0G0
. NOTE: Press
G0
through
G 1
D
to save. Press NEXT (
DATA
CS RECEIVER 1 FORMAT
ENTRY
5
B
C
E
through
to enter the User Number, followed
9
G0
NOTE: When entering the Area 1
and Area 2 options, press
G0
for a blank.
button to set the cursor to the User Number
"(blank) (blank)" for area 2 options.
for a zero and
for
G 4
) button to
E
Universal High Speed
SIA
Ademco Point ID
Pager
for a blank.
for a ten. Enter
0
for a user code,
D
to save.