Programming the GEM-P816 & GEM-P1632 (v.9A and Earlier)
29
INTERIOR
BYPASS
FIRE/TBL
BYPASS
FIRE/TBL
INTERIOR
(Direct Entry)
A
A
KeyFob
D
Press
to save. Then go to step 1 to enter next Key Fob.
When all Key Fobs are entered, press NEXT (
proceed.
Note: If the Key Fob is converted for Two Button "Emergency Use"
(by cutting an internal jumper), both top or bottom buttons must
be depressed to activate an alarms. In this case, the Aux-1 and
Aux-2 cannot be programmed.
Key Fob Zone Assignment
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 =
point 3; A2 = point 4. Up to 32 key fobs (using 1 button) or 16 key fobs (using 2 buttons) or 8 key fobs (using all 4
buttons) or any combination up to a maximum of 32 controlled zones can be assigned, providing multiple wireless panic
buttons on a system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone
number with description/location. To assign a key fob to a zone: program the keyfob as you would a transmitter, entering
the keyfob's ID code, check sum and point number at the appropriate zone. The "Quick Method" is not allowed. The
zone may be hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output).
NOTE: If assigning a key fob to a zone, the "ON/OFF" buttons on the key fob will no longer arm/disarm the system. The
key fob is converted to a "panic only" device.
ZONE DESCRIPTIONS: GEM-RF4RF cannot be used to enter Zone Descriptions. To enter Zone Descriptions you
must use the GEM-RP1CAe2 Keypad or the Napco Quickloader Software.
(Direct Entry)
33
BYPASS
FIRE/TBL
INTERIOR
BYPASS
FIRE/TBL
INTERIOR
rE
INTERIOR
BYPASS
FIRE/TBL
EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the
Direct Address Program Mode for further programming or press the
and resume normal keypad operation.

Key Fob Transmitters

Keyfobs can be programmed as "Arm/Disarm" devices using the ON and
OFF buttons (refer to control panel installation instructions).
SYS TBL
CHIME
Press the
1 The Key Fob Transmitter number (01–15). Press
2 The area number to which transmitter is assigned (1 or 2); enter 0 to
SYS TBL
CHIME
3 The 6-digit RF ID # printed on the transmitter (enter all numbers and/or
4 The 1-digit checksum number printed on transmitter.
5 The Aux-1 Option (see key fob Aux 1 & Aux 2
6 The Aux-2 Option (see key fob Aux 1 & Aux 2
#
Area #
6-digit RF ID #

Dealer Code

Press the
including leading zeros. Use the
SYS TBL
CHIME
Press the
Re-enter the Dealer Code.
SYS TBL
CHIME
Press
SYS TBL
CHIME
button and for each Key Fob Transmitter, enter:
A
disable keyfob.
letters, including leading "0"s, if any).
options).
options).
Checksum #
NOTE: When programming the ID Code
) button to
E
number:
button directly enter the Dealer Code (default = 456789),
A
button for a zero. Press
0
D
to save. Press NEXT (
C
Aux1 #
"A" =
; "B" =
G 0
"C" =
; "D" =
G 2
"E" =
; "F" =
G 4
through
1
9
D
to save.
) button to proceed.
E
C
button once again to end all programming
again.
A
DATA
AUX 1/AUX 2
ENTRY
OPTIONS
None
(blank)
1
Relay Group 1
2
Relay Group 2
9
Keypad Panic
0
Aux K.P. Panic
B
Instant
C
Toggle Aux
Relay
D
Access Control
G 1 ;
;
G 3
.
G 5
buttons. NOTE:
button to enter the
9