Sequence Of Programming Steps For Dual Barista Controller - Newco CB Dual Service Manual

Commercial barista series
Hide thumbs Also See for CB Dual:
Table of Contents

Advertisement

Introduction (Continued)

Sequence Of Programming Steps For Dual Barista Controller

Simultaneously depress and hold the left & middle brew buttons until display lights up (approx. 10 seconds).
You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the
following table.
Use the middle brew button to cycle through the functions to find the one you wish to change.
Use the left brew button to raise the displayed value and the right brew button to lower the value. Press middle brew
button to store the changed value and advance to the next function.
If the brewer detects no activity for approximately 60 seconds it will exit the Program Mode, except as noted below.
Code
Function To Set
1A
Brew 1 time
1b
Brew 2 time
1c
Brew 3 time
2A
Brew 1, double dump feature
2b
Brew 2, double dump feature
2c
Brew 3, double dump feature
3
Visa - Brew Time
4
Water Temperature 1
5
Auto Arm
6A
Pre-infusion 1 mode 2
6b
Pre-infusion 2 mode 2
6c
Pre-infusion 3 mode 2
7
Pulse brew mode
7A
Pulse brew 1 time 3
7b
Pulse brew 2 time 3
7c
Pulse brew 3 time 3
8A
Audible alert/mode
8b
Audible alert no. of beeps
9
Coffee freshness monitor
10A
Filtering flow rate
10b
Filter capacity 4
11
Number of brews
Auto warmer shutoff 5
12A
12b
Time interval before shutoff
13A
Power mode
13b
Power shutdown time 6
End
None 7
1.
Brewer will remain in this sequence indefinitely until Cancel button is pressed. Heating icon will track heater operation.
2.
Hidden when corresponding brew time is OFF
3.
Hidden if pulse brew mode is off or corresponding brew time is OFF.
4.
Hidden if filter flow rate is off.
5.
Warmer models only.
6.
Hidden when power save mode is normal.
7.
Program mode will time out in 15 seconds at end of programming sequence.
20-Aug-12
Set Values Available
OFF, 30 sec – 8 mins
OFF, 30 sec – 8 mins
OFF, 30 sec – 8 mins
ON or OFF
ON or OFF
ON or OFF
OFF, 30 sec – 2.5 mins
170 F – 205 F
ON or OFF
ON or OFF
ON or OFF
ON or OFF
ON or OFF
OFF, 30 sec – 8 mins
OFF, 30 sec – 8 mins
OFF, 30 sec – 8 mins
ON or OFF
Off, 1 – 9
10 mins – 2 hrs
OFF, 0.25 – 1.00 gal. /min
OFF, 0.50 – 2.50 gal. X 100
ON or OFF, Clr
ON or OFF
0 – 4:15
Normal, Power Save, Power Down
30 mins – 4 hrs
N/A
Left Side
85 Oz (2:00+/-)
85 Oz (2:00+/-)
170 Oz (4:00+/-)
170 Oz (4:00+/-)
255 Oz (6:00+/-)
255 Oz (6:00+/-)
OFF
OFF
OFF
OFF
OFF
OFF
1:00
1:00
202
202
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
4:30
4:30
5:00
5:00
6:30
6:30
ON
ON
4
4
2 HRS
2 HRS
OFF
OFF
OFF
OFF
N/A
N/A
N/A
N/A
N/A
N/A
Normal
Normal
N/A
N/A
N/A
N/A
Right Side
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cb-2Cb-5Cb-7

Table of Contents