GE PD900 Installation Instructions Manual page 14

Self-cleaning radiant electric drop-in range
Hide thumbs Also See for PD900:
Table of Contents

Advertisement

Installation Instructions
Alternate Construction Preparation
Optional Maintop Filler or Back-
AA
guard Kit
If counter opening extends to the wall, it will
require Maintop Filler Kit (JXS66XX) or Back-
guard Kit (JXS36XX or JXS39SS) to close the
gap.
NOTE: If the countertop is greater than 25" ,
it will show a gap between the backguard
and wall or between filler kit and the wall.
If the countertop is less than 25" , a gap will
occur between the countertop front and the
control panel ends.
(See page10, D3).
Wall
9/16"
Must Be
Flat
Refer to the Filler or Backguard Kit
instructions for Installation details.
25"
9/16"
30"
Smooth Cut
Must Be Level
AB
AC
Must Be
Level
Must Be
Flat
14
Island Installation
When installing in an island or other
non-standard location, countertop cutout
dimensions must be according to page 5.
For the anti-tip bracket instructions, see
page 9.
In this application, do not use Backguard Kit
(JXS36XX or JXS39SS).
Cabinets Over The Range
Less Than 30"
If a 30" clearance between cooking surface
and overhead combustible material or
metal cabinets cannot be maintained,
protect the underside of the cabinets
above the cooktop with not less than 1/4"
insulating millboard covered with sheet
metal not less than 0.0122" thick.