14.5
Reassembly of parts removed
for servicing
All parts are replaced in reverse order to
removal.
14.6
Flue system
-
Check externally to make sure that fl ue
is not blocked
-
Inspect fl ue system to make sure that
all fi ttings are tight and secure.
14.7
Operation of fan
-
Switch on electrical supply and turn on
gas.
-
Set selector switch to 'Winter'
tion.
-
Light burner by operating external con-
trols (if fi tted) to call for heat.
-
Do not light the boiler without the sealed
chamber cover fi tted
-
Check that fan operates when burner lit
and stops when it goes out.
15 Replacement of parts
Warning!
•
Before starting the replacement of
parts, read the "Safety instructions"
chapter carefully.
15.1
To replace fan
-
Slide fl ue sensing probe insulating boot
away from fan.
-
Pull off both red and white sensing
probe tubes.
-
Disconnect power supply and earth
leads to fan.
-
Slacken, but do not remove, two screws
securing fan to rear of fl ue hood.
-
Supporting fan, unscrew and remove
two screws securing fan to front of fl ue
hood.
-
Lower fan from top of boiler then tilt
base of fan to right hand side. Gently
ease fan forwards and out of boiler.
-
Transfer fl ue sensing probe assembly
onto replacement fan.
-
Fit replacement fan in reverse order to
removal.
Note: Ensure white air sensing tube is con-
nected to upper probe and red tube to
lower probe.
posi-
15.2
To replace air pressure switch
-
Locate air pressure switch in upper right
hand corner of sealed chamber.
-
Pull off plastic tubes from base of
switch.
-
Remove electrical connections from
switch.
-
Unscrew and remove two screws secur-
ing switch to upper panel and remove
switch.
-
Fit electrical connections to replacement
switch as follows:
NO - BROWN
NC - BLACK
C
-
Fit replacement switch in reverse order
to removal.
Important: Refi t red tube to right hand
connector and white tube to left hand
connector.
40
- BLUE