Vertical Flue Preparation And Fitting - Saunier Duval EnviroPlus F24e Instructions For Use Installation And Servicing

High efficiency condensing combination boiler; high efficiency condensing system boiler
Table of Contents

Advertisement

VERTICAL FLUE
ADAPTOR KIT
Pt.No. A2024900
8.7 Vertical Flue
These instructions are for the installation of this vertical flue and
its accessories only. Diagram 8.7 shows the Vertical Flue
Adaptor kit and Accessories.
Lubricate the rubber seals prior to inserting flue pipes.
Make sure all joints are properly fitted, sealed and secured.
Remove all burrs from cut pipes.
You can either cut the 1 metre extension pipes cutting equal
amounts off both the air duct and flue duct, cut the plain end not
the flared end where the sealing rings are fitted, or use the
400mm - 500mm metre adjustable pipe to make up the required
flue length.
Note: The 400mm-500mm telescopic pipe if used is fitted to the
top outlet of the appliance.
Your selected flue arrangement must be secured with fixing
brackets. One fixing bracket to be used for every metre of flue
pipe used.
The terminal should be positioned as to cause the least problem
with the dispersal of products of combustion and any pluming
that may occur.
The use of weather collars are the preferred method when
installing the roof terminal.
An Example Vertical Flue Installation. (The flue assembly is an
entirely push fit design), see diagram 8.8.
Terminal Installation, see diagram 8.9.
2000225294A

8 Vertical Flue Preparation and Fitting

ROOF TERMINAL
Pt.No. 08510300
1M EXTENSION
Pt.No. 08509900
FLAT ROOF
WEATHER COLLAR
Pt.No. 08510700
PITCHED ROOF
WEATHER COLLAR
Pt.No. 08510500
400mm-500mm
TELESCOPIC PIPE
Pt.No. 08510000
26
45° BEND
Pt.No. 08510200
90° BEND
Pt.No. 08510100
FIXING
BRACKET
Pt.No. 08512000
Diagram 8.7