5. • Bleed each radiator to remove air, ensure all
bleed screws are re-tightened.
• If necessary repressurise the system, refer to
procedure 4
7. • Ensure the display indicates a system pressure
of 1.0 bar adjust if necessary.
14.1 Adjusting the Central heating output.
The central heating output is factory preset to
approximately :
- 15 kW for Themaclassic F30E/F30E SB.
- 20 kW for Themaclassic F35E.
If a different central heating output is required, proceed as
follows :
MANOMETER
SW1
DIP
SWITCH
Factory set in
"OFF" position
14.2 Dip Switches
The position of the SW1Dip Switch(es), see diagram 14.2, and
PUMP OPERATION
DIP SWITCH 1
CONTINUOUS
WITH BURNER
CONTINUOUS
WITH HEATING
DEMAND
FACTORY SETTING
4000123924-2
14 Commissioning
maxi
15 kW
P.
max.
mini
0
+
DIP SWITCH 2
ON
ON
ON
OFF
OFF
ON
OFF*
OFF*
* GB/IE PREFFERED SETTING
6.
• Leave cap open on automatic air vent.
8. • Open various hot water taps to bleed system
To gain access to potentiometer P3, unclip the control box,
see diagram 13.3.
The potentiometer P3, is shown in diagram 14.2, to adjust
to the required heating output, insert a small flat edge screw
driver into the arrowed slot in potentiometer P3, turn
clockwise to adjust to the desired setting. Use a manometer
to monitor the burner pressure.
maxi
15 kW
P.
max.
mini
P3
P6
the table below can be used to change the operation of the
pump and maximum heating temperature of your boiler.
HEATING TEMP
O
53
C
O
87
C
O
53
C
O
73
C
30
POTENTIOMETER P3
P3
POTENTIOMETER P6
P6
P7
USER
INTERFACE
BOARD
Diagram 14.2
DIP SWITCH 3
DIP SWITCH 4
ON
ON*
OFF
OFF
ON
OFF*
ON
OFF