Insulation Pads/Ceramic Fibre, Glass yarn
These can cause irritation to skin, eyes and the respiratory tract.
If you have a history of skin complaint you may be susceptible
to irritation. High dust levels are usual only if the material is
broken.
Gas Leak or Fault
If a gas leak or fault exists or is suspected, turn the boiler mains
electrical supply off and turn off the gas supply at the meter.
Consult your local gas company or your local installation/
servicing company.
Electrical Supply Failure
The boiler will not work without an electrical supply.
Normal operation of the boiler should resume when the electrical
supply is restored. If not, the boiler safety cut-off may have
operated, please refer to the following section to reset.
Reset any external controls, to resume normal operation of the
central heating.
To Operate the Boiler
1. Check that all isolating valves are open with their slots in line
with the length of the valve, see diagram 7.1.
2. A sealed pressurised system must be filled and
pressurised by a competent person.
Only operate the boiler when you are sure that the system has
been filled and pressurised. Check this by looking at the
pressure gauge which should read a minimum of 1.0bar, see
diagram 1.
Important Information
Instructions for Use

Operating the Boiler

FASCIA
RESET
BUTTON
Normal handling should not cause discomfort, but follow normal
good hygiene and wash your hands before eating, drinking or
going to the lavatory.
If you do suffer irritation to the eyes or severe irritation to the skin
seek medical attention.
Reset Button
Refer to diagram 1 which shows the fascia behind the drop
down door.
If the burner goes out check the digital display. Flashing digits
on the display indicate a fault. Allow the boiler to cool down for
at least four minutes then press the 'reset' button. This should
restart the boiler.
To obtain service call your installer or Heatcall (Saunier Duval's
own service organisation) using the telephone number given on
the front page of these instructions.
MODE
DIGITAL
BUTTON
DISPLAY
3. If you are in any doubt about the boiler being filled with water
contact your installation/servicing company or the local gas
company.
4. Check that the electrical supply to the boiler is ON at the
external isolator.
5. Set any remote controls as required.
6. If the display is flashing, press the 'reset' button, shown on
diagram 1.
7. The boiler should now operate.
3
PRESSURE
GAUGE
Diagram 1
221879A