Domestic Hot Water System Design; Boiler Schematic - Saunier Duval ISOMAX F 28 E Installation And Operating Instructions Manual

Wall mounted modulating combination boiler
Table of Contents

Advertisement

DOMESTIC HOT WATER SYSTEM DESIGN

Copper tubing or plastic Hep
the domestic hot water system. Unnecessary
pressure losses should be avoided.
A flow restrictor limiting the flow through the boiler
to a maximum of 16 l/min is fitted to the boiler.
The boiler will operate with a minimum supply
pressure of 0,7 bar, but under reduced flow rate.
Best operating comfort will be obtained from a sup-
ply pressure of 1 bar.

BOILER SCHEMATIC

1
- Domestic thermistor
2
- Three way valve
3
- Gas valve
4
- Gas valve ignition module
5
- Temperatur sensor for accumulation vessel
6
- Accumulation vessel
7
- Burner
8
- Ignition electrode
9
- Combustion chamber
10 - Heating safety valve (3 bar)
11 - Main heat exchanger
12 - Air pressure switch
13 - Flow detector
14 - DHW pump
15 - Non return valve
16 - Bypass
17 - Domestic heat exchanger
18 - Heating pump
19 - Heating expansion vessel
20 - Heating thermistor
21 - Overheat safety thermostat
22 - Flame sensor electrode
23 - Fan
24 - Domestic safety valve (6 bar)
25 - Loss of water sensor
26 - Domestic expansion vessel
27 - Pressure/temperature relief (7 bar)
28 - Domestic safety valve (10 bar)
A - Heating return
B
- Cold water inlet
C - Heating flow
D
- Domestic hot water outlet
E
- Gas
D1 - Discharge from HTG safety valves
D2 - Discharge from DHW safety valves
D3 - Discharge from temp/press (to tundish)
Valve
Minimum
Minimum
outlet size
size of
size of
discharge
discharge
to tundish
pipe D2
from
tundish
G 1/2
15 mm
22mm
28 mm
35 mm
G 3/4
22 mm
28 mm
35 mm
42 mm
G 1
28 mm
35 mm
42 mm
54 mm
8
0 may be used for
2
19
Maximum
Resistance
resistance
created by
allowed
each elbow or
expressed as a
bend
length of
straight pipe
i.e. no elbows
or bends
up to 9 m
0.8 m
up to 18 m
1.0 m
up to 27 m
1.4 m
up to 9 m
1.0 m
up to 18 m
1.4 m
up to 27 m
1.7 m
up to 9 m
1.4 m
up to 18 m
1.7 m
up to 27 m
2.3 m
'Hard Water Areas'
In areas where the water is 'hard', more than
200mg/litre, it is recommended that a proprietary
scale reducer is fitted in the cold water supply to
the boiler.
23
11
21
9
7
22
8
20
18
2
16
17
14
15
25
13
10
28
A
B
C
D1
D1
D2
D1
Diagram 6
Discharge from HTG+
domestic prv on jig
D2
D1
Diagram 6a
12
27
6
3
4
1
D E
D3
D1
Discharge from DHW
safety valves
D3
Tundish
5
26
24
Gully